Liting Chen1,2, Jianhao Shen1,2, Gang Xu1,2

  • 1College of Urban Transportation and Logistics, Shenzhen Technology University, Shenzhen 518118, China.

PubMed
概括

本研究引入了一种新方法,用于早期检测使用启动电流封膜能量在感应电机中间转速短路故障. 该方法实现了高精度,提高了发动机的维护和可靠性.

相关概念视频

Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
149
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
93
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
104
Back EMF01:24

Back EMF

Generators convert mechanical energy into electrical energy, whereas motors convert electrical energy into mechanical energy. A motor works by sending a current through a loop of wire located in a magnetic field. As a result, the magnetic field exerts a torque on the loop. This rotates a shaft, extracting mechanical work from the electrical current sent in initially. When the coil of a motor is turned, magnetic flux changes through the coil, and an emf (consistent with Faraday's law) is...
3.0K
Energy Stored in Inductors01:16

Energy Stored in Inductors

An inductor is ingeniously crafted to accumulate energy within its magnetic field. This field is a direct result of the current that meanders through its coiled structure. When this current maintains a steady state, there is no detectable voltage across the inductor, prompting it to mimic the behavior of a short circuit when faced with direct current.
In terms of gauging the energy stored within an inductor, it is equivalent to the integral of the power delivered at every individual moment, all...
401
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...