扩散排序光谱中的信号噪声比:有多好是足够好吗?
Jamie Guest1, Peter Kiraly1,2, Mathias Nilsson1
1Department of Chemistry, University of Manchester, Oxford Road, Manchester, M13 9PL, UK.
Magnetic resonance (Gottingen, Germany)
|October 31, 2023
概括
扩散顺序的NMR光谱 (DOSY) 的准确性取决于信号对噪声的比率和实验参数. 其他错误来源限制了扩散域精度改进的时间平均化.
科学领域:
- 核磁共振 (NMR) 光谱学 核磁共振 (NMR) 光谱学
- 分析化学 分析化学
- 物理化学 物理化学
背景情况:
- 扩散顺序的NMR光谱 (DOSY) 提供基于拉莫尔频率和扩散系数的多维光谱.
- 在DOSY中扩散域的准确性受到实验数据的不确定性的影响,包括信号与噪声比.
- 在DOSY光谱中,峰值位置和宽度由分别的扩散系数和适配误差来确定.
研究的目的:
- 在2D DOSY实验中研究信号与噪声比,实验参数和扩散域精度之间的关系.
- 评估各种错误来源对DOSY扩散域数据可靠性的影响.
- 通过DOSY中信号平均化来确定可实现的精度改进的极限.
主要方法:
- 使用克拉梅尔-拉奥下界来理论评估不确定性.
- 采用蒙特卡洛模拟来模拟错误传播.
- 进行实验性DOSY测量以验证理论发现.
主要成果:
- 在DOSY.中证明了信号与噪声比和扩散域精度之间的直接相关性.
- 确定实验参数显著影响扩散系数估计的可靠性.
- 确认非噪声错误源对信号平均的准确性收益施加了上限.
结论:
- 信号与噪声比是DOSY中精确的扩散域表示的关键因素.
- 优化实验参数对于最大限度地提高DOSY结果的可靠性至关重要.
- 由于固有的实验错误限制,时间平均为提高DOSY准确性提供了有限的好处.
相关概念视频
¹H NMR: Interpreting Distorted and Overlapping Signals
1.0K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.0K
¹³C NMR: ¹H–¹³C Decoupling
1.1K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K
Two-Dimensional (2D) NMR: Overview
696
The 1D NMR spectrum of large and complex molecules like natural products has complicated splitting patterns and overlapping signals, which can be easily interpreted using 2-dimensional (2D) NMR. Unlike 1D NMR, 2D NMR has two frequency axes that provide the coupling information between the nucleus A and nucleus B in a molecule. The process from which 2D spectra are obtained has four steps.
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
696
NMR Spectrometers: Resolution and Error Correction
704
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
704
Nuclear Overhauser Enhancement (NOE)
712
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the Nuclear Overhauser Enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring...
712
NMR Spectroscopy: Chemical Shift Overview
1.5K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
1.5K