8.2m/s的脉冲波速度作为与心血管目标器官损伤存在相关的值
Sayuri Inuzuka1, Priscila Valverde de Oliveria Vitorino2, Adriana Sebba Barroso1
1Universidade Federal de Goiás - Liga de Hipertensão Arterial, Goiânia, GO - Brasil.
Arquivos brasileiros de cardiologia
|November 1, 2023
概括
脉冲波速度 (PWV) 8.2 m/s对于早期检测高血压相关心血管损伤,包括左心室缩和心血管斑块,最为敏感.
科学领域:
- 心血管医学 心血管医学
- 高血压研究 高血压研究
- 诊断生物标志物 诊断生物标志物
背景情况:
- 对于脉冲波速度 (PWV) 存在既定的正常值和参考值.
- 与心血管生物标志物最强烈相关的特定PWV值尚不清楚.
研究的目的:
- 为了确定PWV值最能预测高血压患者的目标器官损伤 (TOD).
- 为了将PWV与左心室缩 (LVH),内心介质厚度 (IMT) 增加和大脑动脉斑块相关联.
主要方法:
- 在119名高血压患者的横截面研究.
- 接收器运行特征 (ROC) 曲线分析以评估生物标志物相关性.
- 统计学意义设置为p < 0.05.05.
主要成果:
- ROC分析显示PWV值为8.1m/s (LVH),8.2m/s (IMT) 和8.7m/s (状斑块).
- 8.2m/s的PWV最好地确定了所有三个TOD生物标志物.
- PWV>8.2 m/s与LVH (p<0.001) 有显著的相关性,带斑块 (p=0.003) 和增加的IMT (p=0.004).
结论:
- 8.2m/s的PWV显示了对高血压中心血管TOD早期检测的高灵敏度.
- 这一PWV值是识别高风险患者的关键指标.
相关概念视频
Pulse
543
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
543
Pulse amplitude and quality
1.8K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
1.8K
Blood Pressure
3.1K
The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
3.1K
Cardiovascular System Abnormal Findings I: Inspection and Palpation
415
In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
Abnormal findings observed during an inspection
415
Equipments Used To Measure Blood Pressure
984
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
984
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K