无树和高速率金属电池由无机丰富的SEI维持
Xueyu Lian1, Zhijin Ju2, Lin Li3
1College of Energy, Soochow Institute for Energy and Materials Innovations, SUDA-BGI Collaborative Innovation Center, Key Laboratory of Advanced Carbon Materials and Wearable Energy Technologies of Jiangsu Province, Soochow University, Suzhou, 215006, P. R. China.
Advanced materials (Deerfield Beach, Fla.)
|November 2, 2023
概括
这项研究介绍了一种经过修改的电流收集器,可以防止金属电池中的树生长. 这一创新提高了未来储能应用的电池性能和安全性.
科学领域:
- 材料科学 材料科学 材料科学
- 电化学 电化学 电化学
- 储能 储能 储能 储能 储能 储能
背景情况:
- 金属电池对储能充满希望,但由于阳极树突的形成而受到影响.
- 树突导致不稳定的固体电解质介相 (SEI) 和不均的沉积.
研究的目的:
- 开发一个双修改的电流采集器,用于无树的阳极.
- 为了提高金属电池的可逆性和稳定性.
主要方法:
- 调节一个电流采集器的电子结构.
- 电子显微镜 (cryo-EM) 和X射线深度分析用于SEI分析.
- 用修改和标准电流采集器制造和测试金属电池.
主要成果:
- 实现了无树的阳极,具有稳定的,富含无机物SEI.
- 增强的离子导电性和均的沉积.
- 提高了速率能力 (400小时在50 mA cm−2) 和低温性能 (-50 °C).
结论:
- 经过修改的电流采集器使高性能,安全的金属电池成为可能.
- 可扩展的生产为可持续能源储存的成本降低提供了潜力.
- 双修改策略对于稳定金属阳极是有效的.
相关概念视频
Batteries and Fuel Cells
27.5K
A battery is a galvanic cell that is used as a source of electrical power for specific applications. Modern batteries exist in a multitude of forms to accommodate various applications, from tiny button batteries such as those that power wristwatches to the very large batteries used to supply backup energy to municipal power grids. Some batteries are designed for single-use applications and cannot be recharged (primary cells), while others are based on conveniently reversible cell reactions that...
27.5K
Electrolysis
26.5K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
26.5K
Potentiometry: Membrane Electrodes
595
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
595