使用基尔IV装置在长期集成双入口模式下对 (生物) 亚酸盐的聚合同位素分析
Mattia Tagliavento1, Sven Hofmann1, Michael Ernst Böttcher2,3,4
1Institute of Geosciences, Goethe University Frankfurt, Frankfurt am Main, Germany.
Rapid communications in mass spectrometry : RCM
|November 13, 2023
概括
生物酸盐的聚合同位素 (Δ47) 分析现在需要更少的材料,可以准确地确定已灭绝的脊椎动物的体温. 一种新的方法有效地去除了二次石,改善了古气温重建.
科学领域:
- 古气候学 古气候学
- 地质化学 地质化学
- 古生物学的古生物学
背景情况:
- 聚合同位素 (Δ47) 分析生物酸衍生的二氧化碳对于确定灭绝的脊椎动物体温至关重要.
- 传统的方法需要大样本大小,并与二次石污染作斗争.
研究的目的:
- 为了评估基尔IV装置在Δ47分析中减少样本大小的有效性.
- 测试一种预处理方法,用于从生物酸盐中去除二次石.
- 为已灭绝的脊椎动物建立准确的古气温测量.
主要方法:
- 使用基尔IV装置进行Δ47分析,测试带有和没有水槽的模式.
- 应用1M酸 (pH5) 预处理来去除二次酸盐.
- 通过基于双入口的质谱法比较结果.
主要成果:
- 具有水槽的基尔IV装置显著降低了样本大小要求.
- 生物酸盐 (不包括牙) 的 Δ47 值与纯碳酸盐的统一温度关系相匹配.
- 酸预处理成功地恢复了生物酸/酸盐混合物的原始Δ47值.
结论:
- 通过基尔IV装置和有效的水分去除,可以对低有机生物酸盐 (例如,质) 进行准确的Δ47分析.
- 1M酸 (pH5) 预处理1小时有效地从含碳酸盐的酸盐中去除二次酸盐.
更多相关视频
12:48Measuring Cation Transport by Na,K- and H,K-ATPase in Xenopus Oocytes by Atomic Absorption Spectrophotometry: An Alternative to Radioisotope Assays
Published on: February 19, 2013
10.6K
05:41Rapid Mix Preparation of Bioinspired Nanoscale Hydroxyapatite for Biomedical Applications
Published on: February 23, 2017
19.3K
相关概念视频
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
233
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
233
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
664
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
664
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
754
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
754