无YOLO-IR:一种改进的算法,用于在红外图像中实时检测车辆
Zixuan Zhang1, Jiong Huang2, Gawen Hei3
1College of Automation, Nanjing University of Information Science & Technology, Nanjing 210044, China.
Sensors (Basel, Switzerland)
|November 14, 2023
概括
这项研究介绍了YOLO-IR-Free,这是一个改进的算法,用于实时红外探测车辆. 它通过使用无方法和用于挑战低对比度图像的新注意力机制来提高准确性和速度.
科学领域:
- 计算机视觉 计算机视觉
- 人工智能的人工智能
- 机器学习 机器学习
背景情况:
- 红外车辆检测对于交通安全和智能驾驶系统至关重要,特别是在不利的条件下.
- 现有的方法在低对比度,小物体检测和红外成像中的实时性能方面扎.
- 轻量级的物体检测算法经常面临这个任务的速度和准确性之间的权衡.
研究的目的:
- 开发一个改进的,实时的红外车辆检测算法.
- 为了解决当前处理低对比度和小物体的方法的局限性.
- 为了提高检测速度和轻物体检测准确度之间的平衡.
主要方法:
- 提出了YOLO-IR-Free,这是一个基于改进的注意力机制YOLOv7.7的无算法.
- 引入了一种新的注意力机制和网络模块,以捕捉微妙的纹理和低对比度的特征.
- 用无头取代基于的检测头,以提高检测速度.
主要成果:
- 与其他方法相比,YOLO-IR-Free表现出优越的性能.
- 实现了更高的准确性,回忆率和平均精度得分.
- 保持有效的实时检测性能.
结论:
- YOLO-IR-Free有效地解决了实时红外探测车辆的挑战.
- 提出的注意力机制和无设计显著提高了性能.
- 这种算法为增强交通安全和智能驾驶提供了一个有前途的解决方案.
相关概念视频
Infrared (IR) Spectroscopy: Overview
1.9K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
1.9K
IR Frequency Region: Fingerprint Region
911
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
911
Difference from Background: Limit of Detection
6.4K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
6.4K
IR Spectrum
1.0K
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
1.0K
IR Frequency Region: X–H Stretching
984
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
984
Linear time-invariant Systems
263
A system is linear if it displays the characteristics of homogeneity and additivity, together termed the superposition property. This principle is fundamental in all linear systems. Linear time-invariant (LTI) systems include systems with linear elements and constant parameters.
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
263


