复杂酸性介质中的量化:了解规范和缓解带移动的情况
Heather M Felmy1, Nathan P Bessen1, Hope E Lackey1
1Energy and Environment directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
ACS omega
|November 16, 2023
概括
化学系统中的矩阵效应可能对在线监测具有挑战性. 这项研究使用光学光谱学和化学模型在复杂介质中证明了的强有力的量化.
科学领域:
- 分析化学 分析化学
- 频谱学是一种光谱学.
- 核化学 核化学 核化学
背景情况:
- 在线监测在化学分析中提供了显著的优势.
- 由化学相互作用引起的矩阵效应使实时化学系统分析复杂化.
- 酸和酸介质中的烯离子为核能和一般化学系统提供了一个相关的案例研究.
研究的目的:
- 用光学光谱学研究和解决乌兰离子系统中的矩阵效应.
- 应用和比较多变量曲线分辨率和HypSpec用于物种分析.
- 在复杂的化学环境中使用化学计量建模来证明强大的量化.
主要方法:
- 在现场和实时光学光谱学 (拉曼和可见).
- 多变量曲线分辨率 (MCR) 和HypSpec用于光谱解卷.
- 用于定量分析的化学建模.
主要成果:
- 证明了矩阵效应对乌兰离子光谱指纹的影响.
- 通过使用MCR和HypSpec.成功地解解复杂物种.
- 在复杂的酸性混合物中实现了强大的量化.
结论:
- 光学光谱学与化学测量建模相结合,有效地克服了矩阵效应.
- 开发的方法为在具有挑战性的化学环境中量化提供了可靠的方法.
- 这项研究提供了一种可转移的方法,用于在各种化学应用中进行在线监测.
相关概念视频
EDTA: Auxiliary Complexing Reagents
596
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
596
Extraction: Advanced Methods
455
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
455
Complexometric Titration: Overview
7.2K
Complexometric titration involves the formation of a complex by reacting a metal ion with one or more ligands. A visual indicator often detects the end point of a complexometric titration. It is added to the metal solution before the titration, forming a stable metal–indicator complex and imparting color to the solution. As the titration approaches the equivalence point, the excess of the added ligand displaces the indicator from the metal–indicator complex, releasing the free...
7.2K
Atomic Absorption Spectroscopy: Lab
457
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
457
Complexometric Titration: Ligands
963
Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
963
UV–Vis Spectrometers
1.4K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.4K