对于具有和非线性度的离散时间交换系统,事件触发的H∞控制
Qian Wang1, Yuetao Yang1, Fujie Tian1
1School of Automation, Hangzhou Dianzi University, Hangzhou 310018, China.
ISA transactions
|November 17, 2023
概括
本研究介绍了对具有和的离散时间交换系统的事件触发的H∞控制. 该方法确保了系统稳定性,同时节省了通信和计算资源.
科学领域:
- 控制理论 控制理论
- 系统工程 系统工程
- 应用数学 应用数学 应用数学
背景情况:
- 开关系统在控制应用中很普遍,但在输入/状态和方面面临挑战.
- 事件触发的控制策略对于现代系统中高效的资源管理至关重要.
研究的目的:
- 为具有输入和状态和的离散时间交换系统开发事件触发的H∞控制策略.
- 为了保证指数稳定性,使用平均停留时间 (ADT) 方法.
- 为了节约通信和计算资源.
主要方法:
- 使用凸船体方法设计状态反和动态输出反控制器.
- 引入一个动态事件触发机制.
- 应用平均停留时间 (ADT) 方法进行稳定性分析.
主要成果:
- 消除输入和状态和对系统性能的不利影响.
- 通过动态事件触发机制,大大节省了通信和计算资源.
- 保证了闭环系统的指数稳定性.
结论:
- 拟议的事件触发的H∞控制方法有效地解决了离散时间切换系统中的和问题.
- 动态事件触发机制提高了资源效率.
- 基于ADT的方法确保了强大的稳定性和性能.
更多相关视频
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
8.7K
10:51An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
13.8K
相关概念视频
Feedback control systems
317
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
317
Time and frequency -Domain Interpretation of PI Control
132
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
132
Transient and Steady-state Response
186
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
186
Control System Problem
119
In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
119
Second Order systems II
114
In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
114
Linear time-invariant Systems
262
A system is linear if it displays the characteristics of homogeneity and additivity, together termed the superposition property. This principle is fundamental in all linear systems. Linear time-invariant (LTI) systems include systems with linear elements and constant parameters.
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
262