储存温度对DLP打印件尺寸稳定的影响
Yeh Lee1, Shimin Wang2, Pengtao Yan3
1Master's Candidate and Resident, Department of Prosthodontics , Peking University School and Hospital of Stomatology, Beijing, PR China.
The Journal of prosthetic dentistry
|November 17, 2023
概括
储存温度显著影响数字光处理 (DLP) 印刷牙模具的尺寸稳定性. 在4°C时观察到最佳稳定性,前后牙区域之间存在差异.
科学领域:
- 添加剂制造 添加剂制造 添加剂制造
- 牙科材料科学 牙科材料科学
- 生物材料工程 生物材料工程
背景情况:
- 关于存储条件对3D打印对象的准确性和维度稳定性的影响的研究有限.
- 了解这些影响对于3D打印牙科模型的临床应用至关重要.
研究的目的:
- 为了评估储存温度对数字光处理 (DLP) 印刷牙造型尺寸稳定性的影响.
- 为了研究前后牙区域对不同储存温度的不同反应.
主要方法:
- 部类型被3D扫描并用立方体进行修改以进行维度分析.
- 使用DLP技术打印件,并在密封袋中储存在-20°C,4°C,20°C和37°C的温度下.
- 立方体距离在28天内测量,数据使用ANOVA和Tukey的HSD测试进行分析.
主要成果:
- 在4°C保存的件在所有测量区域显示出最高的维度稳定性.
- 在-20°C存储的件显示出最小的尺寸变化,而在20°C和37°C存储的件则显示出扩张.
- 在前 (P1) 和后 (P2,P3) 牙区域之间观察到显著的尺寸变化差异.
结论:
- 建议在4°C的温度下储存DLP打印牙膏,以获得最佳的维度稳定性.
- 储存温度显著影响3D打印牙科模型的准确性,区域差异很大.
- 进一步的研究应该探索长期稳定性和其他环境因素的影响.
相关概念视频
Cold Weather Concreting
74
When freshly poured concrete is exposed to freezing temperatures before it has set, the water within the concrete can freeze. This expansion disrupts the setting process, delays chemical reactions necessary for hardening, and increases the volume of pores within the hardened concrete, which weakens its overall structure. If the concrete manages to reach an appreciable strength before it freezes, the damage can be somewhat mitigated.
To counteract the negative impacts of cold weather, ensuring...
To counteract the negative impacts of cold weather, ensuring...
74
Mass Concreting
71
Mass concreting refers to the process of placing large volumes of concrete, such as in gravity dams. The heat generated during the cement hydration process and differential cooling rates within the concrete mass can lead to a temperature gradient, which can result in thermal cracks in the concrete mass.
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
71
Hot Weather Concreting
67
Concreting at elevated temperatures accelerates the hydration process, leading to quicker setting but potentially reducing the long-term strength of the concrete structure. Additionally, low air humidity fosters rapid moisture loss from the concrete, resulting in reduced workability, pronounced plastic shrinkage, and a higher likelihood of crazing.
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
67
Drying Shrinkage
80
When hardened concrete is exposed to air with a relative humidity of less than 100 percent, it begins to lose the free water within its capillaries. As this water evaporates, the water initially adsorbed onto the calcium silicate hydrates migrates towards these now empty spaces and eventually evaporates as well. Over time, as more water leaves, the volume of the concrete decreases, a phenomenon known as drying shrinkage.
A portion of this drying shrinkage can be reversed; if the concrete is...
A portion of this drying shrinkage can be reversed; if the concrete is...
80
Design Example: Managing Concrete Workability
83
This example deals with managing the workability of concrete for a raft foundation project under hot weather conditions. Workability is crucial for ensuring the concrete is easy to place, compact, and finish. In this scenario, a slump test — a common method to measure the workability of fresh concrete — initially indicated low workability. This was attributed to the rapid water loss from the concrete mix, exacerbated by the high temperatures causing the course aggregates to heat up.
83