在具有周期动态的序列中最大限度地减少流器件
Sebastian Flassbeck1,2, Jakob Assländer1,2
1Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
Magnetic resonance in medicine
|November 23, 2023
概括
这项研究引入了一种新的k空间重新排序方法,以减少定量MRI中的流器件. 该技术有效地将周期脉冲序列中的图像扭曲最小化,具有平衡的梯度时刻.
科学领域:
- 磁共振成像 (MRI) 是一种磁共振成像技术.
- 医学物理 医学物理
- 图像重建 图像的重建
背景情况:
- 流是定量MRI中重要的人工制品的来源.
- 这些工件来自于平衡梯度时刻序列中的大k空间跳跃.
- 尽量减少这些文物对于准确的定量MRI至关重要.
研究的目的:
- 开发和评估一种方法来最大限度地减少流器件.
- 专注于有平衡梯度时刻的周期脉冲序列.
- 提高定量MRI数据的质量.
主要方法:
- 提出了一个新的k空间重新排序方案.
- 在重复之间交换个别的k空间线,以尽量减少时间跳跃.
- 优化问题是使用模拟回火算法来解决的.
- 这种方法利用了采样旋转动态的周期性.
主要成果:
- 在重建图像中观察到的流器件的大幅减少.
- 与默认订单相比,定量参数图显示了显著的工件减少.
- 一个最小化所有k空间跳跃的算法变体同样显示了略低的文物水平.
结论:
- 拟议的k空间重新排序有效地减少了流器件.
- 这种方法提高了定量MRI的准确性.
- 它提供了一种有效的方式来获取数据,同时最大限度地减少文物,建立在以前的方法.
更多相关视频
相关概念视频
Magnetic Damping
467
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
467
Eddy Currents
1.6K
Since eddy currents occur only in conductors, magnets can separate metals from other materials. For example, in a recycling center, trash is dumped in batches down a ramp, beneath which lies a powerful magnet. Conductors in the trash are slowed by eddy currents, while nonmetals in the trash move on, separating from the metals. This works for all metals, not just ferromagnetic ones.
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
1.6K
NMR Spectrometers: Resolution and Error Correction
700
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
700
Double Resonance Techniques: Overview
216
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
216
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
809
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
809
Effective Value of a Periodic Waveform
552
The concept of effective value, the root mean square (RMS) value, is crucial in understanding electrical circuits and power delivery. This idea emerges from the necessity to measure the effectiveness of a voltage or current source in supplying power to a resistive load.
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
552