概括
这项研究介绍了一种新的煤炭泥填充技术,用于绿色矿山废物处理. 工程测试证实了其可行性,用于减少采矿业务对环境的影响.
科学领域:
- 采矿工程 采矿工程 采矿工程
- 环境科学 环境科学
- 地质技术工程 地质技术工程
背景情况:
- 在高产量的煤矿中,煤处理带来了重大的环境挑战.
- 现有的煤炭污染管理方法往往缺乏效率和环保性.
- 集成地下填充,接和超负荷断裂知识对于可持续的解决方案至关重要.
研究的目的:
- 提出并详细介绍一项新技术,用于用煤炭泥填充GOAF,以进行绿色处理.
- 为了澄清这一创新填充技术的原则,技术框架和过程.
- 为实际应用开发和评估不同的系统布局和接方法.
主要方法:
- 开发了一种技术框架,整合了煤泥填充,矿山黄泥接和超负荷断裂演化.
- 建立了三种泥填充系统 (地面集中,协调,地下集中) 和三种接方法 (低,相邻,高层).
- 在海达泽和黄陵号的两个特定技术模型上进行了工程测试. 两个煤矿.
主要成果:
- 制定了七种不同的技术模型,用于用煤泥填充GOAF.
- 工程测试验证了地面和地下协调粉碎的可行性,低层和相邻的接.
- 模拟测试为低层和相邻的接技术提供了洞察力.
结论:
- 拟议的煤泥填充技术为绿色和低干扰的采矿废物处理提供了可行的解决方案.
- 这项研究为进一步对煤泥填充技术的理论研究奠定了基础.
- 成功的实地测试证明了开发方法在现实世界采矿场景中的实际适用性.
更多相关视频
06:34Operation of a 25 KWth Calcium Looping Pilot-plant with High Oxygen Concentrations in the Calciner
Published on: October 25, 2017
7.9K
11:14Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
12.4K
相关概念视频
Slump Test
233
The slump test is a widely used method to measure the workability of concrete. It employs a 12-inch high truncated cone mold that tapers from eight inches at the base to four inches at the top. Before testing, the mold is securely attached to a flat base and dampened.
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
233
Compacting Factor test
164
The compacting factor test is a method used to assess the workability of concrete. It is especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
164
Flow Table Test
160
The flow table test is an established method used to assess the workability of concrete, particularly useful for evaluating highly flowable concrete mixes. This test employs an apparatus that consists of a wooden board topped with a steel plate, collectively weighing 35 pounds. The board is connected to a base via a hinge and measures 27.6 inches on each side.
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
160
Additives and Fillers in Concrete
99
Additives and fillers are integral to enhancing the properties of concrete. Pozzolans and blast-furnace slag are additives or admixtures due to their reactions with calcium hydroxide released during cement hydration. Fillers, which are finely ground and similar in fineness to Portland cement, improve concrete attributes such as workability density, and reduce capillary bleeding or cracking. Some fillers possess hydraulic properties or participate in benign reactions within the cement paste.
The...
The...
99
Testing Water Quality
114
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
114
Porosity in Cement Paste
143
The porosity of concrete is a measure of the void spaces within its structure. These spaces impact its strength and durability significantly. When water and cement interact, a chemical reaction called hydration creates a semi-solid paste. This paste includes combined water, making up approximately 23% of the cement's dry mass, and gel water, which fills minuscule voids known as gel pores, accounting for about 28% of the cement gel volume.
The balance of water to cement in the mix is...
The balance of water to cement in the mix is...
143