一种用于多天线无线中继网络的新型计算和转发中继方法
Xuan Yang1, Jiaqi Yan1, Yonggang Xu1
1School of Information and Control Engineering, China University of Mining and Technology, Xuzhou 221116, China.
Entropy (Basel, Switzerland)
|November 24, 2023
概括
连续扩展计算和转发 (SECoF) 通过结合矩阵投影和干扰取消来增强无线中继网络. 这种新的方法提高了网络性能,克服了传统方法的局限性.
科学领域:
- 无线通信无线通信
- 网络编码 网络编码
- 信号处理 信号处理
背景情况:
- 传统的计算和转发 (CoF) 使接收器能够通过执行传输代码单词的整数组合来利用无线通信中的干扰.
- 现有的CoF方法面临挑战,包括等级失败,单个天线限制和最短向量问题,阻碍了复杂网络的性能.
- 需要先进的 CoF 策略来解决多源,多中继和多天线无线中继网络中的这些局限性.
研究的目的:
- 为先进的无线中继网络引入和分析一种新的连续扩展计算和转发 (SECoF) 策略.
- 为了克服传统的Cof的局限性,特别是价格退化和等级失败.
- 在计算速率,排名失败概率和中断概率方面提高整体网络性能.
主要方法:
- 通过整合矩阵投影和连续干扰取消技术开发了SECoF.
- 使用LLL基于格子的分辨率算法,为整数值系数向量找到近似解决方案.
- 为SECoF策略衍生出简洁的数学公式.
主要成果:
- 拟议的SECoF方法有效地克服了传统CoF固有的率趋于零和排名故障问题.
- 与现有的最先进的方法相比,SECoF表现出强大的稳定性,并显著提高了网络性能.
- 模拟结果验证了SECoF在计算速率,排名失败概率和中断概率方面的卓越性能.
结论:
- SECoF为多源,多中继和多天线无线中继网络提供了一种先进和有效的解决方案.
- 矩阵投影和连续干扰取消的整合为干扰利用提供了一个强大的框架.
- 在物理层网络编码方面,SECoF提供了显著的进步,提高了无线通信系统的效率和可靠性.
相关概念视频
Pilot and Numeric Relaying
86
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
86
Directional Relays
118
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
118
Mesh Analysis for AC Circuits
379
In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
379
Differential Relays
144
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
144
Line Protection with Impedance Relays
82
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
82
Maximum Power Transfer
264
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
264