仪器仪表开发,改进,简化和小型化:用于质谱仪表的多功能板源
Sarah Trimpin1,2, Ellen Inutan3, Hope Coffinberger2,4
1Wayne State University, Detroit, MI, USA.
European journal of mass spectrometry (Chichester, England)
|November 24, 2023
概括
大气下压力电离质谱 (MS) 提供了对各种样品的直接分析. 这种新的板源概念能够在传统实验室环境之外实现快速,灵敏和强大的MS应用.
科学领域:
- 分析化学 分析化学
- 质谱测量质量谱测量
背景情况:
- 质谱学 (MS) 在学术实验室之外具有巨大的潜力.
- 直接电离方法对于现实世界样本分析至关重要.
研究的目的:
- 介绍一个新的板源概念用于亚大气压 (AP) 离子化MS.
- 展示该系统对各种样本进行直接分析的能力.
主要方法:
- 利用一个板源直接将样本引入到一个国家/地区的副AP区域.
- 用于分析挥发性和非挥发性分子的副AP电离MS.
- 证明了适应多种无通风的离子化方法的适应性.
主要成果:
- 实现了小到大分子的直接,准确,敏感和直接分析.
- 成功分析了多样化和"脏"的现实世界样本.
- 展示了子AP电离MS系统的稳定性和速度.
结论:
- 板源概念显著扩大了MS的应用范围.
- 副AP电离MS为环境电离提供了一个实用且安全的替代方案.
- 这项技术有助于在各个领域更广泛地采用MS.
相关概念视频
Tandem Mass Spectrometry
1.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.0K
Mass Spectrometers
5.6K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.6K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
753
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
753
Mass Analyzers: Common Types
617
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
617
Mass Spectrometry: Complex Analysis
793
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
793
Mass Analyzers: Overview
685
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
685