对具有有限样本的模拟电路的故障诊断策略,基于变压器和发电模型的组合
Zhen Jia1, Qiqi Yang1, Yang Li2
1School of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China.
Sensors (Basel, Switzerland)
|November 25, 2023
概括
本研究介绍了一种新的故障诊断方法,用于使用深卷积生成对抗网络 (DCGAN) 和变压器架构的模拟电路. 该方法有效地解决了有限的故障样本,即使使用最小的数据,也可以达到超过96%的准确性.
科学领域:
- 电气工程 电气工程
- 人工智能的人工智能
- 信号处理 信号处理
背景情况:
- 模拟电路在电子系统中至关重要,但由于缺陷样本有限,故障诊断具有挑战性.
- 现有的诊断方法在对模拟电路故障检测的数据不足方面扎.
研究的目的:
- 为模拟电路提出一种创新的故障诊断方法.
- 为了克服在诊断性能中缺陷样本不足的局限性.
主要方法:
- 将深层卷积生成对抗网络 (DCGAN) 与变压器架构集成.
- 使用连续波段转换与Morlet波段用于时间频率图像生成.
- 通过DCGANs产生的合成时间频率信号来增强数据集.
主要成果:
- 拟议的方法在各种单一和多重故障场景中实现了超过96%的整体准确性.
- 即使只有150个真实故障数据样本,也表现出令人满意的性能.
- 在比较分析中表现优于既定基准方法.
结论:
- 结合的DCGAN和变压器方法有效地提高了对有限数据的模拟电路故障诊断.
- 该方法为需要高诊断精度的现实应用提供了强大的解决方案.
- 时间频率图像分析和数据增强是提高诊断性能的关键.
相关概念视频
Transformers with Off-Nominal Turns Ratios
160
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
160
Equivalent Circuits for Practical Transformers
437
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
437
Power System Three-Phase Short Circuits
91
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
91
Three-Winding Transformers
234
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
234
Differential Relays
142
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
142
Transformers
1.1K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.1K