导航在胸脚架螺丝摆放中的影响对螺丝的准确性和螺丝直径/脚架宽度的比率
Eric Mandelka1, Jula Gierse1, Felix Zimmermann1
1Research group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), Department of Orthopedics and Trauma Surgery, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany.
Brain & spine
|November 29, 2023
概括
脊柱导航提高了胸脊柱脚螺丝的精度,并允许更大的螺丝选择. 这种技术也显示出减少辐射暴露和运行时间的趋势.
科学领域:
- 神经外科 神经外科
- 整形外科手术 整形外科手术
- 脊柱外科手术 脊柱外科手术
背景情况:
- 胸椎脚螺丝的位置准确性对于脊柱的稳定性至关重要.
- 脊柱导航提高了螺丝放置的准确性,但它对螺丝对脚踏的比率的影响还没有得到充分研究.
研究的目的:
- 为了评估脊柱导航对胸脊柱脚螺丝精度的影响.
- 为了评估导航对螺丝直径和脚宽度比的影响.
主要方法:
- 对45名接受导航螺丝安置的患者进行前性研究.
- 使用光镜指导与匹配的对照组进行比较.
- 对螺丝精度和螺丝直径与脚宽度比率的分析.
主要成果:
- 导航组显示了明显更高的螺丝精度.
- 导航组显示,螺丝直径与脚宽度的比率显著增加了~10%.
- 导航趋向于较低的手术内辐射剂量和操作时间.
结论:
- 导航胸柱脚架螺丝放置提高了准确性和螺丝选择.
- 改进的螺丝与脚踏的比率可能会对固定强度产生积极影响.
- 导航不会对手术时间或辐射暴露产生负面影响.
相关概念视频
Design of Transmission Shafts
The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by reconfiguring the...
Stress Concentrations in Circular Shafts
Consider the elastic torsion formula, which applies to a circular shaft with a consistent cross-section. This formula assumes that the shaft's ends are loaded with rigid plates firmly attached. However, in many cases, torques are applied to the shaft through mechanisms like flange couplings or gears, which are connected by keys inserted into keyways. This application method modifies the stress distribution near the point of torque application, causing it to deviate from the distributions...
Torsion of Noncircular Members
Circular shafts undergoing torsional stress maintain their cross-sectional integrity due to their axisymmetric nature. This symmetry ensures an even distribution of stress, allowing the shaft to withstand torsion without distorting. In contrast, square bars, lacking this axial symmetry, experience significant distortion across their cross-sections when subjected to torsion, with the exception of along their diagonals and at lines connecting midpoints. A detailed examination of a cubic element...
Deformations in a Transverse Cross Section
When a material is subjected to uniaxial stress, it elongates or contracts in the direction of the applied force, and also undergoes changes in the perpendicular directions. This behavior is crucial for understanding how materials behave under stress and is governed by mechanical properties such as Poisson's ratio v, which measures the ratio of transverse strain to axial strain.
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Beams with Unsymmetric Loadings
Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Errors in Taping
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...


