铁幻觉:一个独特的案例,接烟雾颗粒在MRI中出现金属工件
Mariam Malik1, Rana Bilal Idrees2, Jawairia Arif2
1Radiology, Atomic Energy Cancer Hospital, Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, PAK.
Cureus
|November 29, 2023
概括
含有氧化铁的接烟雾颗粒可以在脑MRI扫描上引起金属人工物,模仿化病变. 放射科医生需要提高意识,以避免误诊这些职业暴露人工制品.
科学领域:
- 放射学 放射学是指放射学
- 职业健康 职业健康 职业健康
背景情况:
- 磁共振成像 (MRI) 上的金属工件可以来自各种来源.
- 众所周知,偏磁性材料,例如接烟雾中的氧化铁,会导致易感人造物.
研究的目的:
- 报告一个接烟雾颗粒导致MRI头皮工件的案例.
- 为了提高放射科医生对这种特定工件的认识.
- 为了防止错误诊断化病变或其他头皮病理.
主要方法:
- 一个52岁的男性工业检查员出现头痛的案例报告.
- 进行了无对比的脑部MRI,揭示了头皮信号异常.
- 详细的患者病史显示,在成像之前,职业接触接烟雾.
主要成果:
- 磁力共振扫描显示了头皮上许多小的,圆形的焦点与改变的信号,可疑是化病变.
- 临床检查显示没有头皮异常.
- 追溯历史发现接烟雾暴露是MRI工件的原因,原因是磁性敏感性.
结论:
- 接烟雾颗粒可以在头皮MRI上引起特征性的易感性人造物质.
- 这些文物可能被误认为是化病变,需要放射科医生仔细评估.
- 职业病史对于准确解释暴露个体的MRI发现至关重要.
相关概念视频
Magnetic Resonance Imaging
5.2K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.2K
Imaging Studies I: CT and MRI
252
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
252
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
485
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
485