功能值功率和 (制造) 关键功率争议
Stephen Wong1, Mark Burnley2, Alexis R Mauger1
1School of Sport and Exercise Sciences, University of Kent, Canterbury, UK.
Journal of sports sciences
|November 30, 2023
概括
这封信是针对最近关于运动生理学概念的通讯中的事实错误. 作者澄清他们的工作并不是主要集中在关键力量概念上.
科学领域:
- 运动生理学 运动生理学
- 运动科学 运动科学 运动科学
背景情况:
- 多坦最近的一份报告包含了有关运动生理学的不准确信息.
- 这些不准确性涉及到诸如批判力和生理学解释等概念.
研究的目的:
- 为了解决最近的一份通讯中存在的重大事实错误和虚假陈述.
- 为了澄清Wong等人研究的范围和发现. (2022年) 的第二季.
主要方法:
- 批判性审查和反驳在通讯中提出的具体观点.
- 专注于严重的错误和过时的生理解释.
主要成果:
- 多坦的通讯包含了许多事实上的错误和过时的生理学解释.
- 作者的以前的工作 (Wong等,2022) 被误解了,并不是主要关注关键力量.
结论:
- 通信中的临界力概念和相关的生理学解释是不准确的.
- 需要进一步澄清,以纠正有关运动生理学研究的科学记录.
相关概念视频
Maximum Power Transfer
263
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
263
Maximum Power Flow and Line Loadability
119
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
119
Power in a Three-Phase Circuit
328
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
328
Complex Power
426
Power engineers have introduced the concept of complex power to determine the cumulative effect of parallel loads. This idea plays a crucial role in power analysis because it encompasses all the details related to the power consumed by a specific load.
Complex power is defined as the multiplication of the voltage and the complex conjugate of the current. The magnitude of this power, known as apparent power, is measured in volt-amperes (VA). Notably, the angle of the complex power equates to the...
Complex power is defined as the multiplication of the voltage and the complex conjugate of the current. The magnitude of this power, known as apparent power, is measured in volt-amperes (VA). Notably, the angle of the complex power equates to the...
426
Power Factor Correction
182
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
182
Power System Three-Phase Short Circuits
91
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
91