使用夜间灯光和社交媒体跟踪电力损失及其感知原因
Samuel W Kerber1, Nicholas A Duncan1, Guillaume F L'Her1,2
1Department of Mechanical Engineering, The Colorado School of Mines, Golden, CO 80402, USA.
iScience
|November 30, 2023
概括
这项研究使用卫星数据和社交媒体来监测城市地区的停电及其原因. 调查结果揭示了公众对政府对广泛停电负有责任的看法.
科学领域:
- 城市基础设施弹性 城市基础设施弹性
- 遥感和社交媒体分析.
背景情况:
- 关键基础设施,如电力,对于城市的社会经济稳定至关重要.
- 在无法进入或受冲突影响的地区,评估基础设施状况,尤其是电力供应状况,是很困难的.
- 传统的地面层数据收集通常不适合监测广泛的干扰.
研究的目的:
- 用卫星图像和社交媒体数据展示一种用于监控停电的新方法.
- 分析公众对城市环境中停电原因的看法.
- 评估使用遥感和社交媒体进行基础设施监控的可行性.
主要方法:
- 利用夜间照明卫星数据确定委内瑞拉加拉加斯的停电范围 (2019年3月).
- 使用推特数据进行情绪分析和主题建模,以了解公众的看法.
- 进行统计分析,将卫星数据与社交媒体活动和公共话语相关联.
主要成果:
- 在停电期间,在夜间光线强度和Twitter活动之间观察到一个反向关系.
- 提到委内瑞拉总统的推特显示,消极和指责相关术语的增加.
- 在社交媒体上反映的公众看法表明,人们相信政府对停电负有责任.
结论:
- 卫星图像和社交媒体分析为监控像停电这样的大规模基础设施中断提供了可行的替代方案.
- 在社交媒体上对公众情绪的分析可以提供对基础设施故障的感知原因的见解.
- 这种方法对于传统数据收集具有挑战性的地区尤其有价值.
更多相关视频
06:16An Experimental Approach to Investigating Effects of Artificial Light at Night on Free-Ranging Animals: Implementation, Results, and Directions for Future Research
Published on: February 2, 2022
2.4K
06:19Low-Cost Automated Flight Intercept Trap for the Temporal Sub-Sampling of Flying Insects Attracted to Artificial Light at Night
Published on: December 29, 2021
2.6K
相关概念视频
Electrical Energy
1.2K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.2K
Lossy Lines and Overvoltages
89
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
89
Reducing Line Loss
155
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
155
Line Loss
246
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
246
Energy Losses in Transformers
880
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
880