研究水下车辆执行器的复合故障诊断技术,具有定位错误约束
1Jiangsu University of Science and Technology, Zhenjiang, Jiangsu, 212100, China.
Heliyon
|November 30, 2023
概括
这项研究引入了水下车辆执行器的新复合故障诊断技术,通过分析运动力和结合定位错误约束来提高准确性和安全性. 该方法提高了在水下机器人中复杂的执行器故障的诊断效率.
科学领域:
- 机器人技术 机器人技术 机器人技术
- 机械工程 机械工程
- 错误诊断 错误诊断 错误诊断 是一个
背景情况:
- 当前执行器故障诊断缺乏运动力分析,导致错误和精度低.
- 水下车辆执行器的安全性对于任务的成功和运营完整性至关重要.
研究的目的:
- 为水下车辆执行器提出一种新的复合故障诊断技术.
- 为了提高在定位错误约束下执行器故障诊断的准确性和安全性.
主要方法:
- 分析水下机器人执行器运动力的分析.
- 基于受控执行器运动的实时数据参数提取.
- 在模型构建的定位误差约束下,复合故障特征的深度融合.
主要成果:
- 拟议的技术成功诊断了复合执行器故障.
- 观察到在水平轴上的定位误差有显著的改善.
- 复合执行器故障的增强诊断效果.
结论:
- 开发的技术为诊断水下车辆执行器的复合故障提供了一种可靠的方法.
- 这种方法有助于提高水下机器人执行器的操作安全性.
相关概念视频
Root-Locus Method
157
A cruise control system in a car is designed to maintain a specified speed automatically by adjusting the gas pedal. The system continuously measures the vehicle's speed and makes fine adjustments to the pedal to achieve this goal. The root locus method is particularly useful for understanding how the cruise control system's behavior changes under varying conditions, such as when the car goes uphill, downhill, or faces strong wind resistance.
This system can be represented by a block...
This system can be represented by a block...
157
Fault Types
89
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
89
Line Protection with Impedance Relays
82
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
82
Errors in Global Positioning System
47
Global Positioning System (GPS) technology has revolutionized navigation and positioning, but its accuracy is often compromised by various errors. These errors, stemming from environmental, satellite, and receiver-related factors, require careful mitigation to ensure reliable performance across applications.Atmospheric ErrorsGPS signals travel through the Earth’s ionosphere and troposphere, introducing delays which affect accuracy. The ionosphere is strongly influenced by charged particles,...
47
Directional Relays
118
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
118
Three-Phase Short Circuit—Unloaded Synchronous Machine
147
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
147