儿童化温度测绘方法:快速识别致病微生物
Takashi Ishikawa1, Yoji Uejima2, Masashi Okai1
1Division of Immunology, National Center for Child Health and Development, Tokyo, Japan; Department of Pediatrics, Jikei University School of Medicine, Tokyo, Japan.
概括
融化温度 (TM) 方法在患有血流感染 (BSI) 的儿童中提供快速的细菌鉴定,显示出高准确性,特别是在阴性病例中,甚至在抗生素治疗期间.
科学领域:
- 微生物学 微生物学
- 分子诊断学 分子诊断
- 儿童传染病 儿童传染病
背景情况:
- 融化温度 (TM) 映射方法利用内在的16S核糖体RNA基因 (16SrDNA) 融化温度模式,直接从全血中识别细菌物种.
- 这项研究探讨了TM对儿科患者血液感染 (BSI) 的临床实用性.
研究的目的:
- 评估TM方法在诊断儿童细菌血流感染方面的临床应用.
- 为了比较TM的性能与传统的血液培养 (BC) 方法.
主要方法:
- 在日本一家儿童医院 (2018-2021) 进行的一项前性观察研究.
- 在疑似或确诊的BSI患者中,研究了TM和BC之间的匹配率,识别时间和细菌DNA数量.
- 包括81名患者 (93个样本).
主要成果:
- TM 显示了与BC.的高负匹配率 (97%).
- TM和BC之间的整体匹配率为78%.
- TM在4.7小时的中位数提供了识别,比BC快得多,即使在服用抗生素后也可以识别细菌.
结论:
- 作为儿科BSI的快速诊断工具,TM显示出希望,在负面结果中提供高准确度.
- 该方法在抗生素治疗期间识别细菌的能力及其速度比传统的血液培养具有显著的临床优势.
相关概念视频
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Microbial Growth Measurement: Direct Methods
Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
Physical Methods for Controlling Microbial Growth: Temperature
Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
Automated Microbial Diagnostics
Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...


