光电子动量显微镜在直接和动量空间成像中使用紫外线光子源的性能
Tzu Hung Chuang1, Chuan Che Hsu1, Wei Sheng Chiu1
1National Synchrotron Radiation Research Center, Hsinchu, Taiwan.
Journal of synchrotron radiation
|December 1, 2023
概括
光电子相关图像和纳米光谱 (PRINS) 显微镜提供先进的成像和光谱. 它实现了用于表面科学应用的高空间,动量和能量分辨率.
科学领域:
- 表面科学和凝聚物质物理学
- 光谱和显微镜技术的使用.
背景情况:
- 台湾光子源光线线27A2具有光电子相关图像和纳米光谱 (PRINS) 终端站.
- 这个终端站配备了一种光电子动量显微镜,用于直接空间成像,动量空间成像和位置敏感光辐射光谱.
研究的目的:
- 为了展示PRINS光电子动量显微镜的性能和功能.
- 用标准样本和光子源评估仪器的空间,动量和能量分辨率.
主要方法:
- 使用Hg灯和He (I) 辐射作为内部光子源.
- 在一个棋盘图案样本和一个Au(111) 单晶上进行了直接空间和动量空间成像.
- 在费米边缘分析了金色图案的强度概况和光电子强度,以估计分辨率.
主要成果:
- 实现了50nm的空间分辨率,0.0172 Å-1的动量分辨率和26 meV的80K的能量分辨率.
- 观测到Au(111) Shockley表面状态的Rashba分裂在300 K.
- 从恒能轮模式和动量分辨率光辐射光谱模式中获得的带结构之间显示出密切一致.
结论:
- 普林斯终端站的光电子动量显微镜是用于高级表面分析的高性能仪器.
- 展示的分辨率和功能证实了其适用于对表面状态和电子结构的详细调查的适用性.
相关概念视频
Overview of Electron Microscopy
9.2K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
9.2K
Transmission Electron Microscopy
5.5K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.5K
Overview of Microscopy Techniques
10.4K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
10.4K
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K