对色度,光谱和电化学技术进行比较,以量化硫化
Susmit Mhatre1, Anjali Rai1, Hatim Ali1,2
1Department of Pharmacy Sciences, School of Pharmacy & Health Professions, Creighton University, Omaha, NE 68178, USA.
BioTechniques
|December 7, 2023
概括
在溶液中量化硫化 (H2S) 是一个挑战. 与H2S检测的色度测量和色谱技术相比,电化学方法提供了更高的灵敏度和速度.
科学领域:
- 生物化学 生物化学
- 分析化学 分析化学
背景情况:
- 硫化 (H2S) 是一种具有治疗潜力的内源性气传递物.
- 由于其特性,在生理溶液中精确量化H2S存在重大挑战.
研究的目的:
- 为了比较四种常见的检测和定量水溶液中的H2S的方法.
- 评估色度,色谱和电化学H2S检测技术的性能.
主要方法:
- 一种色度,一种色谱和两种电化学H2S量化方法的比较.
- 在模拟生理溶液中评估灵敏度,反应时间和适用性.
主要成果:
- 颜值测量和染色学方法分别检测出H2S在毫米和微分子水平.
- 电化学方法实现了纳米分子和小分子灵敏度,并且更快.
- 电化学技术显示出更高的灵敏度和效率.
结论:
- 选择H2S量化的方法取决于研究对灵敏度,速度和成本的需求.
- 电化学方法对于敏感和快速的H2S检测具有优势.
- 仔细考虑分析要求对于准确的H2S测量至关重要.
相关概念视频
Spectrophotometry: Introduction
3.2K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
3.2K
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Gas Chromatography: Types of Detectors-II
386
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
386
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
721
Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
721
Indicators
48.7K
Certain organic substances change color in dilute solution when the hydronium ion concentration reaches a particular value. For example, phenolphthalein is a colorless substance in any aqueous solution with a hydronium ion concentration greater than 5.0 × 10−9 M (pH < 8.3). In more basic solutions where the hydronium ion concentration is less than 5.0 × 10−9 M (pH > 8.3), it is red or pink. Substances such as phenolphthalein, which can be used to determine the pH of a solution, are...
48.7K
Potentiometry: Types of Electrodes
673
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
673