在带有超导磁屏蔽的射频陷中同情地冷却高电荷离子
Elwin A Dijck1, Christian Warnecke1,2,3, Malte Wehrheim1,3
1Max Planck Institute for Nuclear Physics, Saupfercheckweg 1, 69117 Heidelberg, Germany.
The Review of scientific instruments
|December 8, 2023
概括
我们在超导陷中使用Be+离子对高电荷离子 (HCI) 进行同情冷却,为量子逻辑光谱和量子比特运算实现了出色的被动磁屏蔽.
科学领域:
- 原子,分子和光学 (AMO) 物理学
- 量子信息科学 量子信息科学
- 计量学 计量学 计量学
背景情况:
- 量子逻辑光谱 (QLS) 能够进行高精度测量和量子运算.
- 高电荷离子 (HCI) 的冷却和捕获对于先进的量子应用至关重要.
- 超导射频共振器为敏感测量提供了独特的环境.
研究的目的:
- 用多普勒冷却的Be+离子来同情地冷却高电荷离子 (HCI).
- 通过使用超导共振器演示被动磁屏蔽.
- 为了使单个HCIs能够进行量子逻辑光谱和量子比特运算.
主要方法:
- 将单个Be+离子和单个HCI限制在一个冷的线性保罗陷中.
- 将陷集成到一个超导射频共振器中.
- 使用Ramsey干扰度和Be+量子位上的自旋回声测量.
主要成果:
- 在一个由Be+离子组成的库伦晶体内实现了HCI的交感冷却.
- 在10^-10 s^-1级测量了持久磁场的微分衰变速率.
- 已证明连贯时间超过400毫秒,表明出色的被动磁屏蔽到直流频率.
结论:
- 在超导陷中对HCI的同情冷却使先进的量子逻辑光谱学成为可能.
- 超导共振器为敏感的量子测量提供了特殊的被动磁屏蔽.
- 这种技术为频率计量和量子比特运算与各种离子物种铺平了道路.
相关概念视频
Mass Analyzers: Common Types
615
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
615
Atomic Nuclei: Nuclear Relaxation Processes
657
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
657
Types Of Superconductors
988
A superconductor is a substance that offers zero resistance to the electric current when it drops below a critical temperature. Zero resistance is not the only interesting phenomenon as materials reach their transition temperatures. A second effect is the exclusion of magnetic fields. This is known as the Meissner effect. A light, permanent magnet placed over a superconducting sample will levitate in a stable position above the superconductor. High-speed trains that levitate on strong...
988
Double Resonance Techniques: Overview
214
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
214
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
870
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
870
Atomic Nuclei: Magnetic Resonance
663
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
663


