在异常单分子排放模式上的测量精度极限
Li Fang1, Fang Huang1,2,3
1Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
bioRxiv : the preprint server for biology
|December 11, 2023
概括
光学偏差降低了单分子定位显微镜 (SMLM) 的分辨率. 本研究量化了对3D SMLM精度的偏差效应,为偏差校正策略提供了指导方针.
科学领域:
- 生物物理学的生物物理.
- 光学显微镜的使用方法
- 纳米技术纳米技术
背景情况:
- 单分子定位显微镜 (SMLM) 为生物研究提供纳米分辨率.
- 来自样本/系统不完美的光学偏差会扭曲点分布函数 (PSF),降低SMLM精度,特别是在3D中.
- 缺乏对SMLM偏差影响的全面分析.
结论:
- 提供了对SMLM精度和波面估计的偏差效应的定量见解.
- 为SMLM开发高效的偏差校正策略奠定了基础.
- 提高3D SMLM的精度和可靠性,用于成像细胞和组织等厚样本.
相关概念视频
Atomic Emission Spectroscopy: Lab
167
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
167
Atomic Emission Spectroscopy: Overview
2.2K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.2K
Atomic Emission Spectroscopy: Instrumentation
488
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
488
Atomic Emission Spectroscopy: Interference
197
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
197
Atomic Absorption Spectroscopy: Interference
777
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
777
NMR Spectrometers: Resolution and Error Correction
700
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
700