使用触觉传感器阵列和正常与剪切脉冲压力传播方法进行动脉定位的幻象研究.
概括
一个新的触觉传感算法准确地定位了辐射动脉,提高了跨辐射手术的安全性. 这项技术旨在减少导管和监测过程中的并发症和程序失败.
科学领域:
- 生物医学工程 生物医学工程
- 医疗器械 医疗器械
- 手术导航 手术导航
背景情况:
- 跨射线接入对于各种心血管手术至关重要.
- 可靠的辐射动脉局部化对于最小化并发症至关重要.
- 超声波引导和手动触摸等现有方法存在局限性.
研究的目的:
- 开发一种新的触觉感知算法,用于准确地定位放射性动脉.
- 为了弥合当前指导技术和手动触摸之间的差距.
- 提高发展中国家的安全性和减少程序性风险.
主要方法:
- 利用一个曲的触觉传感器阵列和一个新的定位算法.
- 杆触觉传感器对剪切负荷和脉冲波传播的不敏感.
- 使用幻影研究验证了该方法.
主要成果:
- 实现了0.58±0.25mm的平均绝对误差 (MAE),超过了比较方法 (0.81±0.57mm).
- 证明改善了动脉定位的准确性和可重复性.
- 定位在一条动脉半径内,减少了缺失或穿孔动脉的风险.
结论:
- 开发的触觉传感算法提供了强大的和可重复的辐射动脉定位.
- 这项技术有可能显著降低动脉手术中的失败率和并发症.
- 它为提高程序安全提供了一个有希望的解决方案,特别是在资源有限的环境中.
相关概念视频
Sites for measruring blood pressure
1.8K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.8K
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Equipments Used To Measure Blood Pressure
975
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
975
Assessment of blood pressure in brachial artery(two-step method)
715
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
715
Pulse Assessment Sites
1.1K
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
1.1K
Pulse
529
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
529