用双光谱测量O2A频段的Ramjet中的温度和速度测量
Optics express
|December 13, 2023
概括
双光谱现在测量Ramjets中的氧气 (O2),这对飞行条件至关重要. 这一进步为先进的航空航天应用提供了精确的温度和速度数据.
科学领域:
- 航空航天工程 航空航天工程
- 频谱学是一种光谱学.
- 流体动力学 流体动力学
背景情况:
- 双光谱 (DCS) 之前已经测量了水蒸气 (H2O) 用于地面测试飞机的流量诊断.
- 在典型的雷射飞行高度上,水蒸气并不丰富,因此需要替代的目标分子.
- 氧气 (O2) 为飞行测量提供了一个可行的替代吸收目标.
研究的目的:
- 为了证明双光谱 (DCS) 在A频段 (13000-13200 cm-1) 的氧气 (O2) 吸收.
- 在地面测试雷射机内,在各种流量条件下应用DCS进行安装温度和速度测量.
- 为了评估DCS测量O2在喷气环境中的精度和不确定性.
主要方法:
- 使用双光谱 (DCS) 针对O2 A频段吸收线.
- 在地面测试雷射机中,在不同的流量条件下进行测量.
- 应用光谱拟合算法来从DCS数据中确定温度和速度.
主要成果:
- 在五分钟内,温度达到3-5%,速度达到7-11%的测量精度.
- 预计温度和速度测量的总不确定性分别为7-9%和8-12%.
- 将DCS测量和不确定性估计与特定测试设施的预测值进行比较.
结论:
- O2 A频段的DCS是一种可行的技术,用于在Ramjet中测量流量,即使是在飞行相关的条件下.
- 证明的精度和不确定性级别适用于表征射器性能.
- 该研究验证了DCS测量与设施预测的相关性,证实了其在航空航天应用中的可靠性.
相关概念视频
Raman Spectroscopy Instrumentation: Overview
428
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
428
Atomic Emission Spectroscopy: Instrumentation
488
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
488
Atomic Spectroscopy: Effects of Temperature
339
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
339
Atomic Absorption Spectroscopy: Instrumentation
745
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
745
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
230
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
230
Atomic Absorption Spectroscopy: Atomization Methods
526
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
526