基于能量图的故障检测和隔离技术的比较研究,应用于煤工厂
Jan Hendrik Smith1, George van Schoor2, Kenneth R Uren1
1School of Electrical, Electronic and Computer Engineering, Faculty of Engineering, North-West University, South Africa.
Heliyon
|December 13, 2023
概括
本研究比较了三种用于工业故障检测和隔离的能量图法. 距离参数和自值分解方法在检测故障方面表现出色,距离参数方法也证明了对隔离的稳定性.
科学领域:
- 热力学和工业工程 热力学和工业工程
- 专注于工业系统中的能量和功率分析.
背景情况:
- 了解能量和能量相互作用对于工业系统监控至关重要.
- 在物理结构上下文中捕捉这些相互作用有助于故障检测和隔离.
研究的目的:
- 为了比较评估三种基于能量图的可视化方法,用于故障检测和隔离.
- 使用真实和模拟的工业工厂数据评估每个方法的灵敏度和稳定性.
主要方法:
- 开发了三种基于能量图的可视化方法:距离参数,自值分解和残余方法.
- 利用来自煤厂的数据和模拟的故障数据进行比较分析.
- 基于故障检测和隔离能力的评估方法.
主要成果:
- 距离参数和自值分解方法在故障检测方面表现出高灵敏度和稳定性.
- 剩余方法在故障检测方面表现中等.
- 距离参数方法在故障隔离中表现出高灵敏度和稳定性,而自值分解显示出不规则的性能.
结论:
- 距离参数方法对于工业系统的故障检测和隔离都非常有效.
- 自值分解适用于故障检测,但对隔离不那么可靠.
- 剩余方法的性能在检测方面中等,在隔离方面不确.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.7K
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
1.9K
相关概念视频
Fault Types
89
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
89
Power System Three-Phase Short Circuits
88
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Three-Phase Short Circuit—Unloaded Synchronous Machine
147
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
147
Bus Impedance Matrix
122
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
122
Line Protection with Impedance Relays
82
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
82
Differential Relays
142
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
142