修改的SVPWM技术用于CMV减少不对称的双三相感应机器驱动器
Manoj K Chaudhury1, Mukesh K Pathak2, Girish K Singh2
1Department of Electrical Engineering, IIT Roorkee, Roorkee, India. mcelect05@gmail.com.
Scientific reports
|December 13, 2023
概括
本研究引入了一种新的SVPWM技术,用于降低双三相感应电机驱动器的常态电压. 修改后的方法显著降低了损坏电压,提高了系统的可靠性和性能.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 电机驱动器 电机驱动器
背景情况:
- 非对称的双三相感应电机驱动器用于大功率应用.
- 来自逆变器的常态电压 (CMV) 会导致绕线绝缘损坏,轴承问题,电磁干扰和泄漏电流.
研究的目的:
- 在双三相感应电机驱动器中分析CMV.
- 为减少CMV提出一种基于空间向量分解的空间向量脉冲宽度调制 (SVPWM) 技术.
主要方法:
- 基于矢量空间分解的SVPWM技术.
- 利用双重三相系统中额外的自由度.
- 拟议方案的实验验证.
主要成果:
- 将CMV降低到直流链路电压的六分之一,而传统SVPWM则为一半.
- 在减少CMV振幅和脉冲方面表现出有效性.
- 在电流中展示了减少的总波扭曲 (THD).
结论:
- 拟议的修改SVPWM技术有效地减少了双三相感应电机驱动器中的CMV.
- 该方法通过减轻绝缘和轴承损坏来提高系统可靠性.
- 实验结果证实了CMV减少和电流质量的显著改善.
相关概念视频
Simplified Synchronous Machine Model
240
The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
In this model, each generator is connected to a...
240
Three-Phase Short Circuit—Unloaded Synchronous Machine
147
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
147
Generation of Three-Phase Voltage
383
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
383
Three-Phase Voltages
235
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
235
Multimachine Stability
163
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
163
Three-Phase Circuits
415
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
415