对细微植物组织扫描电子显微镜技术的比较和开发
Jinhong Yuan1, Lin Yang1, Panpan Yu1
1Engineering Research Center of Crop Genetic Improvement and Germplasm Innovation in Henan Province, College of Life Sciences, Henan Normal University, Xinxiang 453007, China.
Plant science : an international journal of experimental plant biology
|December 16, 2023
概括
扫描电子显微镜 (SEM) 样本准备可以导致细胞变形. 结冷和甲醇固定最好保存微妙的植物细胞,提高SEM成像准确度.
科学领域:
- 植物生物学 植物生物学
- 显微镜技术 显微镜技术
- 材料科学 材料科学 材料科学
背景情况:
- 在扫描电子显微镜 (SEM) 样品准备过程中细胞变形会影响结果的准确性.
- 微妙的样本,特别是植物组织,容易变形.
研究的目的:
- 研究各种制备方法对植物样本细胞变形的影响.
- 确定最佳的SEM制备技术,以最大限度地减少微妙组织中的工件.
主要方法:
- 植物样本根据含水量和组织硬度被归类为"微妙".
- 评估了五种制备方法,在组织和单细胞水平上测量变形.
- 在不同条件下 (冷阶段,电压,喷雾涂层) 评估样本的稳定性和图像质量.
主要成果:
- 结冷和甲醇固定产生了最小的组织变形和优异的细胞形状的保存微妙的样品.
- 较硬的组织容易接受其他基于脱水的制备方法.
- 冷保护剂和低冷阶段温度 (-30°C) 提高了稳定性和图像质量.
- 较大的样本大小和冷阶段的应用改善了光束稳定性.
结论:
- 建议在精细植物样本的SEM制备中使用冷和甲醇固定.
- 优化的样本准备减少了工件,并提高了SEM成像可靠性.
- 了解制备的影响对于准确的显微镜分析至关重要.
相关概念视频
Overview of Microscopy Techniques
10.4K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
10.4K
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
Overview of Electron Microscopy
9.2K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
9.2K
Preparation of Samples for Electron Microscopy
5.4K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.4K