在心力衰竭中远程血液动力学监测的好处
P R D Clephas1, R A de Boer1, J J Brugts1
1Department of Cardiology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands.
Trends in cardiovascular medicine
|December 18, 2023
概括
远程血液动力学监测提供了一种有希望的方法来减少心力衰竭 (HF) 的住院治疗. 通过检测早期的血液动力学变化,这项技术可以及时进行干预,改善患者的结果并减少医疗保健负担.
科学领域:
- 心脏病学 心脏病学
- 生物医学工程 生物医学工程
- 医疗保健服务研究 医疗服务研究
背景情况:
- 心力衰竭 (HF) 仍然是全球死亡和住院的主要原因.
- 随着HF患病率的上升,医院资源受到压力,需要创新的管理策略.
- 传统的监测方法不足以预测即将发生的HF恶化.
研究的目的:
- 审查HF管理中远程血液动力学监测的理由和证据.
- 提供可用的设备和实施策略的概述.
- 突出远程监控的潜力,以减少HF住院.
主要方法:
- 对心力衰竭中远程血液动力学监测研究的文献综述.
- 对设备功能和临床试验数据的分析.
- 讨论实施因素,包括患者选择和数据管理.
主要成果:
- 远程血液动力学监测可以在HF住院治疗前几周检测心内填充压力的变化.
- 这种早期检测有助于及时进行药理干预.
- 成功实施需要结构整合,最佳的患者选择和高效的数据管理.
结论:
- 远程血液动力学监测是一种可行的策略,可以减少与HF相关的住院治疗.
- 早期检测出血动力学变化,使得积极的患者管理成为可能.
- 进一步的研究和标准化的实施协议对于广泛采用至关重要.
相关概念视频
Pulse rhythm
807
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
807
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
436
The activation of the sympathetic nervous system and the renin-angiotensin-aldosterone system (RAAS) contributes to cardiac remodeling, and inhibiting the RAAS is a pharmacological target in heart failure management. As a result, neurohumoral modulation is a crucial treatment principle for managing heart failure. This approach involves using medications like ACE inhibitors (ACEIs), angiotensin receptor blockers (ARBs), β-blockers, mineralocorticoid receptor antagonists (MRAs), and neutral...
436
Heart Failure Drugs: Diuretics
395
Heart failure and kidney perfusion are interconnected in a complex way. Reduced renal perfusion and venous congestion are two significant factors that contribute to renal dysfunction in heart failure. The kidneys, primarily responsible for fluid balance in the body, are adversely affected due to compromised cardiac output and increased venous pressure. In response to reduced renal perfusion, the kidneys activate neurohumoral mechanisms to restore balance. However, these mechanisms can be...
395
Equipments Used To Measure Blood Pressure
975
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
975
Special considerations while measuring blood pressure
725
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
725