在心力衰竭中远程血液动力学监测的好处

P R D Clephas1, R A de Boer1, J J Brugts1

  • 1Department of Cardiology, Erasmus MC University Medical Centre, Rotterdam, the Netherlands.

PubMed
概括

远程血液动力学监测提供了一种有希望的方法来减少心力衰竭 (HF) 的住院治疗. 通过检测早期的血液动力学变化,这项技术可以及时进行干预,改善患者的结果并减少医疗保健负担.

相关概念视频

Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
807
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System01:26

Heart Failure Drugs: Inhibitors of Renin-Angiotensin System

The activation of the sympathetic nervous system and the renin-angiotensin-aldosterone system (RAAS) contributes to cardiac remodeling, and inhibiting the RAAS is a pharmacological target in heart failure management. As a result, neurohumoral modulation is a crucial treatment principle for managing heart failure. This approach involves using medications like ACE inhibitors (ACEIs), angiotensin receptor blockers (ARBs), β-blockers, mineralocorticoid receptor antagonists (MRAs), and neutral...
436
Heart Failure Drugs: Diuretics01:22

Heart Failure Drugs: Diuretics

Heart failure and kidney perfusion are interconnected in a complex way. Reduced renal perfusion and venous congestion are two significant factors that contribute to renal dysfunction in heart failure. The kidneys, primarily responsible for fluid balance in the body, are adversely affected due to compromised cardiac output and increased venous pressure. In response to reduced renal perfusion, the kidneys activate neurohumoral mechanisms to restore balance. However, these mechanisms can be...
395
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
975