Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
18.2K
喉高分辨率计量规范数据的系统审查
Rameen K Walters1, Rachana Gudipudi1, Tamar Gordis1
1Department of Otolaryngology-Head & Neck Surgery, Medical University of South Carolina, Charleston.
American journal of speech-language pathology
|December 21, 2023
概括
标准化高分辨率喉测量仪 (HRPM) 对于评估吞困难至关重要. 本次审查突出了公布的规范值的变化,强调需要一致的协议来建立可靠的参考数据.
科学领域:
- 吞障碍 吞障碍 吞障碍
- 胃肠病学 胃肠病学
- 医疗器械 医疗器械 医疗器械
背景情况:
- 高分辨率喉测量仪 (HRPM) 越来越多地用于喉乱的评估.
- 缺乏标准化的协议和规范性价值阻碍了HRPM的临床采用.
- 建立共识参考值对于有意义地使用HRPM至关重要.
研究的目的:
- 为共同的HRPM指标绘制和比较已公布的规范值.
- 在不同研究中识别HRPM技术和设备的变化.
- 为了促进建立HRPM的共识参考值.
主要方法:
- 对前性和后性研究进行系统审查.
- 包括在健康成年人中通过国际工作组共识定义的HRPM指标的研究.
- 提取关于喉收缩整数 (PhCI) 和上食道关节 (UES) 参数 (IRP,RT,入口,腹内压力) 的数据.
主要成果:
- 包括30项研究,揭示了技术和设备的显著差异.
- 在年轻人中观察到较低的PhCIs和UES综合放松压力 (IRP).
- 较高的UES放松时间 (RT) 与直立姿势,较大的球体大小和较小的导管有关.
结论:
- 协议,设备和软件的显著异质性使得HRPM规范值的数据聚合变得复杂.
- 需要使用标准化HRPM协议进行前性研究.
- 需要更大的健康个体队伍来建立可靠的HRPM参考值.
相关概念视频
Suctioning the Nasopharyngeal Airway
Nasopharyngeal suctioning is a procedure to remove secretions from the upper part of the respiratory tract that the patient cannot clear independently. It helps maintain airway patency and prevents complications such as aspiration pneumonia.
Equipment Required
Equipment Required
Upper GI Series: Barium Swallow
The Barium Swallow Study, or a Barium Esophagogram, is a diagnostic imaging method used to visualize the upper gastrointestinal (GI) tract, including the esophagus, stomach, and small intestine. It employs barium sulfate, a radiopaque contrast material, to provide clear images of the upper digestive system, helping to identify abnormalities, diseases, or structural issues.
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Suctioning the Oropharyngeal Airway
In preparing for oropharyngeal airway suctioning, a nurse must gather all necessary equipment, including a suction unit with tubing, a prepackaged suction kit, sterile gloves, water or saline for irrigation, a water-soluble lubricant, and additional personal protective equipment (such as a gown, mask, and goggles) to control infections.
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Urodynamic Studies: Uroflowmetry
Uroflowmetry is a non-invasive urodynamic test designed to measure various aspects of urination, including volume, flow rate, and the time to void. This test is crucial for diagnosing and assessing conditions such as bladder outlet obstruction, bladder dysfunction, incomplete bladder emptying, incontinence, and urinary tract blockages caused by benign prostatic hyperplasia (BPH) and urethral strictures.Pre-Test Instructions:Before a uroflowmetry test, patients are typically advised to drink...