Natalia Chepelova1, Artem Antoshin1, Sergei Voloshin1
1Institute for Regenerative Medicine, Sechenov First Moscow State Medical University, 8-2 Trubetskaya St., Moscow 119048, Russia.
Journal of functional biomaterials
|December 22, 2023
概括
牙合金的口腔化可以造成伤害. 这项研究发现电流是主要的短期破坏因素,尽管腐蚀离子也会导致毒性.
科学领域:
- 生物材料科学 生物材料科学
- 口腔医学是指口腔医学.
- 毒理学 毒理学 毒理学
背景情况:
- 口腔,由牙合金产生的,可以导致不良影响,如灼热感和炎症.
- 与口腔相关的副作用背后的确切机制尚不清楚,直流和合金腐蚀离子被怀疑是贡献者.
研究的目的:
- 系统地比较电 (直流+腐蚀离子),单独的直流和单独的腐蚀离子的破坏性影响.
- 通过实验室模型确定负责牙科合金副作用的关键因素.
主要方法:
- 使用一种类似于粘膜的体外模型,使用永生的人类角质细胞 (HaCaTs).
- 与高风险的牙科合金Ti64-AgPd和NiCr-AgPd进行了比较.
- 单独评估了协同电,直流和腐蚀离子的作用.
主要成果:
- 电流已成为与口腔内器件电合相关的细胞毒性过程中的主要破坏因素,特别是在短期 (28天) 中.
- 腐蚀离子,特别是Ni2+对协同毒性的贡献被证明.
- 腐蚀离子在长期内可能构成重大危险.
结论:
- 电流可能是口腔环境中牙合金相互作用造成的短期细胞毒性影响的主要原因.
- 腐蚀离子,如Ni2+,在联合毒性中发挥作用,可能是显著的长期风险因素.
- 了解这些因素对于减轻与牙科合金相关的副作用至关重要.
相关概念视频
Voltaic/Galvanic Cells
57.3K
Spontaneous Chemical Reactions
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
Spontaneous redox reactions occur abundantly in nature. The chemical reaction occurring in a disposable AA battery powering our remote controls is one such example of a spontaneous redox reaction. Another example is the immersion of coiled copper wire into an aqueous silver nitrate solution. The reaction shows a gradual, visually impressive color change from colorless to bright blue and the formation of a grey precipitate on the copper wire. In this experiment,...
57.3K
Voltammetry: Factors Affecting Measurements
157
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
157
Galvanometer
2.2K
Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.2K
Standard Electrode Potentials
43.9K
On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
43.9K
Controlled-Current Coulometry: Overview
208
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
208
Voltammograms: Overview
211
Voltammograms are current plots as a function of applied potential, offering insights into electrochemical systems. The shape of a voltammogram depends on how the current is measured and whether convection (heat transfer by fluid movement) is present or absent.
Shapes of Voltammograms
Shapes of Voltammograms
211