Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Relative Motion Analysis - Acceleration01:10

Relative Motion Analysis - Acceleration

361
A slider-crank mechanism converts rotational motion from the crank into linear motion of the slider or vice versa. This mechanism consists of three main parts: the crank, the connecting rod, and the slider. The movement of the slider-crank is an example of general plane motion as the fluctuating angle between the crank and the connecting rod. Consider a segment AB where point A is at the end of the slider and point B is on the diametrically opposite end to point A, on a crack. The variance in...
361
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

614
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
614
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

681
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
681
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

83
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
83
Beams with Unsymmetric Loadings01:17

Beams with Unsymmetric Loadings

122
Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
122
Castigliano's Theorem: Problem Solving01:14

Castigliano's Theorem: Problem Solving

658
The deflection of a simply supported beam that carries a central point load can be analyzed using structural mechanics principles, particularly by applying Castigliano's theorem. This theorem relates the displacement at the load application point to the partial derivatives of the strain energy in the structure. The simply supported beam with a point load at its center has symmetric reaction forces at the supports, each bearing half of the load. The bending moment at any point along the beam...
658

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Gold Nanoparticle Radiosensitization for High-Dose-Rate Brachytherapy: Differential Efficacy of PEG- and RGD-Functionalized Gold Nanoparticles Across 2-Dimensional, 3-Dimensional, and in vivo Prostate Cancer Models.

International journal of nanomedicine·2026
Same author

Five-year follow-up of the SABR-5 trial: primary toxicity analysis of stereotactic ablative radiotherapy for up to five oligometastases.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026
Same author

Influence of radiotherapy dose rate on gold nanoparticle-induced radiosensitization from high dose-rate brachytherapy and external beam therapy.

Medical physics·2026
Same author

Treatment With Stereotactic Ablative Radiation Therapy for Patients With up to 5 Oligometastatic Cancer Lesions: Long-Term Outcomes of the Nonrandomized Population-based Phase 2 SABR-5 Clinical Trial.

International journal of radiation oncology, biology, physics·2026
Same author

Comprehensive analysis of the tumor targeting efficiency of functionalized nanoparticles in an immunocompetent environment.

Scientific reports·2025
Same author

Metastases-directed therapy in addition to standard systemic therapy in oligometastatic castration-resistant prostate cancer in Canada (GROUQ-PCS 9): a multicentre, open-label, randomised, phase 2 trial.

The Lancet. Oncology·2025
Same journal

Synthetic CT-enabled weekly adaptive radiotherapy for nasopharyngeal carcinoma: Optimizing plan adaptation triggers through volumetric-dosimetric monitoring.

Journal of applied clinical medical physics·2026
Same journal

Method for simultaneous selection of treatment isocenters and margins for polymetastatic extracranial stereotactic ablative radiotherapy.

Journal of applied clinical medical physics·2026
Same journal

Pulse‑level characterization of low monitor unit deliveries on a modern linear accelerator using a plastic scintillation detector.

Journal of applied clinical medical physics·2026
Same journal

Improving image quality in terbium-161 phantom imaging: Quantitative evaluation of DEW and TEW scatter correction methods.

Journal of applied clinical medical physics·2026
Same journal

Latent density discrepancies in commercial lung-equivalent inserts and their clinical dosimetric impact.

Journal of applied clinical medical physics·2026
Same journal

Explainable machine learning for patient-specific quality assurance in intensity-modulated radiotherapy based on anatomical structures.

Journal of applied clinical medical physics·2026
查看所有相关文章

相关实验视频

Updated: Jul 7, 2025

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
06:08

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments

Published on: May 26, 2019

7.5K

线性加速器维护成本分析线性加速器维护成本分析

Marco Carlone1, Wayne Beckham2,3, Cheryl Duzenli4,5

  • 1Department of Medical Physics, BC Cancer - Kelowna , Kelowna, BC, Canada.

Journal of applied clinical medical physics
|December 22, 2023
PubMed
概括
此摘要是机器生成的。

医疗线性加速器的维护成本比率估计为3.13%,低于之前的估计. 劳动力成本占这些开支的三分之二,凸显了在放射瘤学中需要熟练技术人员的需求.

关键词:
一个线性加速器.线性加速器组件 线性加速器组件线性加速器维护成本分析维护成本 维护成本服务成本比率是服务成本比率.

更多相关视频

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

11.8K
Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

26.7K

相关实验视频

Last Updated: Jul 7, 2025

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments
06:08

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments

Published on: May 26, 2019

7.5K
Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
07:31

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Published on: May 9, 2014

11.8K
Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
14:11

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis

Published on: March 29, 2016

26.7K

科学领域:

  • 医学物理 医学物理
  • 辐射瘤学 辐射瘤学
  • 医疗保健管理的管理

背景情况:

  • 医疗线性加速器是辐射瘤学中必不可少的,昂贵的设备.
  • 了解它们的服务和维护成本对于预算制定至关重要,尤其是在癌症发病率上升的情况下.
  • 这些机器的当前服务成本数据尚未得到充分确立.

研究的目的:

  • 分析特定机构的医疗线性加速器服务和维护成本.
  • 估计这些关键医疗器械的服务成本比率.
  • 为辐射瘤学部门提供数据,以便更好地进行财务规划.

主要方法:

  • 收集的零部件成本为两年内在32个医疗线性加速器上的服务.
  • 按机器类型,故障区域和服务中心分离的数据.
  • 计算了服务成本比率,不包括软件支持.

主要成果:

  • 估计的服务成本比率为3.13% (95%CI [2.74%,3.52%]).
  • 观察到的服务成本比率的变化在2.14%至5.25%之间.
  • 劳动力成本占服务总支出的三分之二,强调了劳动力的重要性.

结论:

  • 医疗线性加速器的服务成本比率大约是初始资本成本的3.13%.
  • 这一发现低于此前报告的类似设备估计值.
  • 劳动力成本的显著贡献强调了需要熟练的服务技术人员劳动力.