染色,放大和算法条件,以通过深度学习来实现高精度的细胞检测和细胞分类
Katsuhide Ikeda1, Nanako Sakabe2, Chihiro Ito2
1Pathophysiology Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya,Japan.
American journal of clinical pathology
|December 22, 2023
概括
使用YOLOv8的深度学习模型在细胞诊断中对癌细胞检测和分类具有很高的准确性. 这种人工智能技术对临床查应用具有前景.
科学领域:
- 计算病理学计算病理学
- 医学中的人工智能
- 细胞诊断 细胞诊断
背景情况:
- 深度学习模型越来越多地被用于细胞诊断中的自动细胞检测和分类.
- 在开发通用细胞学模型方面仍然存在挑战,原因是放大,染色和假阳性的变化.
研究的目的:
- 评估深度学习模型对通用细胞学应用的性能.
- 研究放大和染色方法对模型准确性的影响.
- 为了应对人工智能基细胞诊断中虚假阳性等挑战.
主要方法:
- 开发了使用You Only Look Once,版本8 (YOLOv8) 算法的深度学习模型.
- 利用了11种类型的人类癌细胞系,使用了帕帕尼科劳和梅-格林瓦尔德-吉姆萨 (MGG) 染色.
- 评估了不同细胞类型,染色方法和放大率的检测和分类率.
主要成果:
- 所有模型的分类率都超过了95.9%.
- 用Papanicolaou染色的模型的最高检测率为92.3%,用MGG染色的模型为91.3%.
- 对象检测和实例细分模型分别达到94.6%和91.7%的检测率,对11种具有帕帕尼科劳染色的细胞类型.
结论:
- YOLOv8人工智能技术在临床细胞诊断查和细胞分类方面表现出足够的性能.
- 对临床标本的进一步研究对于验证YOLOv8的疗效和解决特定细胞学挑战至关重要.
相关概念视频
Flow Cytometry
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
In...
Fixation and Sectioning
Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Methods to Assess Microbial Populations
Assessing microbial populations is crucial for understanding microbial roles in health, ecology, and industry. Various complementary techniques—both culture-based and molecular—enable detailed analysis of microbial abundance, diversity, and function.Viable Plate CountThe viable plate count is a traditional culture-based method used to estimate the number of living microbes in a sample. After serial dilution, the sample is spread onto nutrient agar plates. Each viable cell forms a visible...