基于变化模式分解和随机配置网络的水电发电机组振动趋势的多步预测模型
Shaokai Yan1, Fei Chen1, Jiandong Yang1
1State Key Laboratory of Water Resources Engineering and Management, Wuhan University, Wuhan 430072, China.
Sensors (Basel, Switzerland)
|December 23, 2023
概括
这项研究引入了一种新的多步预测模型,用于水力发电机组振动趋势. 该模型通过准确预测振动变化,提高了运行状态维护和效率.
科学领域:
- 工程 工程师 工程师 工程师
- 数据科学数据科学数据科学
背景情况:
- 轮机振动监测对于水电厂的运行效率和维护至关重要.
- 预测振动趋势有助于主动操作状态维护.
研究的目的:
- 开发和验证水电机组振动趋势的多步预测模型.
- 提高水力发电机组振动预测的准确性和可靠性.
主要方法:
- 变化模式分解 (VMD) 用于将振动信号分解为内在模式函数 (IMF).
- 随机配置网络 (SCN) 用于预测IMF的各个组成部分.
- 一种用于整合多步预测预测的递归策略.
主要成果:
- 提出的模型准确地预测了水力发电机组的振动趋势.
- 使用VMD进行分解有效地稳定了振动信号.
- 综合方法在不同的单元组件中表现出高的预测准确性.
结论:
- 多步预测模型为水电厂的运营策略提供了显著的好处.
- 准确的振动趋势预测支持优化控制策略和提高运营效率.
- 这种方法有助于改善水电单元的维护和性能.
相关概念视频
Multimachine Stability
163
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
163
Wind Turbine Machine Models
136
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
136
Simplified Synchronous Machine Model
239
The Synchronous Machine Model is a fundamental tool in analyzing and ensuring the transient stability of power systems. This model simplifies the representation of a synchronous machine under balanced three-phase positive-sequence conditions, assuming constant excitation and ignoring losses and saturation. The model is pivotal for understanding the behavior of synchronous generators connected to a power grid, particularly during transient events.
In this model, each generator is connected to a...
In this model, each generator is connected to a...
239
Generator Voltage Control
157
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
157
Generation of Three-Phase Voltage
381
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
381
Sequence Networks of Rotating Machines
103
A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
103