用于评估动脉硬性的光电显微镜
Parmis Karimpour1, James M May1, Panicos A Kyriacou1
1Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK.
Sensors (Basel, Switzerland)
|December 23, 2023
概括
动脉硬是血管衰老和心血管疾病风险的标志物,可以使用各种方法来评估. 摄影电流图 (PPG) 是一个有希望的未来工具,用于评估这一关键的健康指标.
科学领域:
- 心血管研究研究心血管研究
- 生物医学工程 生物医学工程
- 老年学是一门学科.
背景情况:
- 血管衰老导致动脉硬,增加心血管疾病 (CVD) 的风险.
- 动脉硬会导致显著的体积,机械和血液动力学变化.
- 心血管疾病仍然是全球主要的死亡原因.
研究的目的:
- 审查目前评估动脉硬性的方法.
- 突出创新,并比较不同技术的优缺点.
- 探索光聚体显微镜 (PPG) 评估血管衰老的潜力.
主要方法:
- 审查关于动脉硬度评估技术的现有文献.
- 对研究趋势的分析,特别是专注于光聚光学 (PPG).
- 既定方法与新兴技术 (如PPG) 的比较.
主要成果:
- 有各种方法来评估动脉硬,有不同的优点和缺点.
- 对PPG进行动脉硬性评估的研究正在迅速扩大.
- PPG被认为是一个有前途的工具,尽管仍在进行研究.
结论:
- 摄影光电显微镜 (PPG) 为评估血管衰老提供了一个潜在的未来方法.
- 需要继续进行研究,以验证和将PPG纳入临床实践.
- 了解和监测动脉硬是减轻心血管疾病风险的关键.
相关概念视频
Assessment of blood pressure in brachial artery(two-step method)
714
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
714
Assessment of blood pressure in brachial artery(one-step method)
596
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
596
Assessment of the Cardiovascular System III: Palpation
342
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
342
Sites for measruring blood pressure
1.7K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.7K
Pulse
521
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
521
Assessing Blood pressure using a doppler ultrasound
1.4K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K