触摸器:一种基于变压器的双塔架构,用于触摸时间信号分类
IEEE transactions on haptics
|December 25, 2023
概括
本研究介绍了Touchformer,这是一个基于变压器的模型,通过改进触觉时间信号识别来增强机器人的感知. 这种新的方法有效地对复杂的触觉数据进行分类,即使采用有限的样本.
科学领域:
- 机器人和人工智能 机器人和人工智能
- 机器学习 机器学习
- 信号处理 信号处理
背景情况:
- 触觉时信号识别对于机器人感知至关重要.
- 现有的方法面临着各种触觉数据集和小样本大小的挑战.
研究的目的:
- 为了提高触觉时间信号数据集的分类性能.
- 使用变压器架构开发一个强大的机器人感知模型.
主要方法:
- 提出了一个基于变压器的双塔模型,命名为Touchformer.
- 使用自我注意力机制分别提取时间和空间特征.
- 采用数据增强来解决小样本数据集特征.
主要成果:
- 在三个公共数据集上,touchformer的表现明显超过了基准模型.
- 该模型表现出更好的识别性能和稳定性.
结论:
- 拟议的Touchformer模型为触觉时间信号分类提供了一个有效的解决方案.
- 这一进步有助于提高机器人的感知能力.
更多相关视频
11:39Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022
2.2K
14:05Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
Published on: January 23, 2017
29.1K
相关概念视频
Design Example
331
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
331
Types Of Transformers
979
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
979
Transformers with Off-Nominal Turns Ratios
157
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
157
