ITC对多散系统的分析:揭示样本异质性的影响
Christian Schönbeck1, Jeppe Kari2, Peter Westh3
1Department of Pharmacy, University of Copenhagen, Denmark.
Analytical biochemistry
|December 26, 2023
概括
结合相互作用中的样本异质性可以在实验中错过,导致低估的结合常量. 结合度的变化带来了更大的挑战,可能导致复杂的结合模型的误解.
科学领域:
- 生物化学 生物化学
- 化学物理 化学物理
- 分子相互作用 分子相互作用
背景情况:
- 结合相互作用经常涉及具有不同亲和度和度的异质样本.
- 标准的实验方法往往假设同质的结合元件,简化复杂的系统.
研究的目的:
- 调查样本异质性对异热定位热量计 (ITC) 实验的影响.
- 分析结合亲和度和度的变化如何影响ITC数据的解释.
主要方法:
- 利用模拟和实验数据来建模结合相互作用.
- 将标准单点模型应用于异质结合系统.
- 对异质性的迹象进行了分析.
主要成果:
- 单位模型可以适应异质数据,当结合自由能量正常分布时,但低估了结合常量.
- 结合度的异质性使图复杂化,可能模仿多位点结合.
- 以前无法解释的实验异常可以归因于样本异质性.
结论:
- 约束相互作用中的样本异质性可能是微妙但重要的,影响实验结果.
- 需要仔细分析来检测和解释ITC研究中的绑定异质性.
- 了解异质性对于准确描述分子相互作用至关重要.
相关概念视频
Polymers: Molecular Weight Distribution
3.4K
For any given polymer, the weight average molecular weight (Mw) is higher than, if not equal to, the number average molecular weight (Mn). The only situation in which the weight average molecular weight and the number average molecular weight are equal is when a polymer consists only of chains with equal molecular weight. However, this never happens in a synthetic polymer, since it is difficult to control the polymerization process up to a molecular level with accuracy to a hundred percent.
3.4K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
478
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
478
Test for Homogeneity
2.0K
The goodness–of–fit test can be used to decide whether a population fits a given distribution, but it will not suffice to decide whether two populations follow the same unknown distribution. A different test, called the test for homogeneity, can be used to conclude whether two populations have the same distribution. To calculate the test statistic for a test for homogeneity, follow the same procedure as with the test of independence. The hypotheses for the test for homogeneity can...
2.0K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
745
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
745
Choosing Between z and t Distribution
2.8K
The z and the Student t distribution estimate the population mean using the sample mean and standard deviation. However, to decide which distribution to use for a calculation, one needs to determine the sample size, the nature of the distribution, and whether the population standard deviation is known. If the population standard deviation is known and the population is normally distributed, or if the sample size is greater than 30, the z distribution is preferred. The Student t distribution is...
2.8K
Ion-Exchange Chromatography
524
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
524