电化学氧化反透缩物使用试点规模的反应电化学膜过系统:性能和机制
Lehui Ren1, Yang Li1, Yun Guo1
1State Key Laboratory of Pollution Control and Resource Reuse, Advanced Membrane Technology Center of Tongji University, Shanghai Institute of Pollution Control and Ecological Security, School of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
Journal of hazardous materials
|December 27, 2023
概括
一个试验规模的反应电化学膜 (REM) 系统有效地处理了高盐度废水. 这种电化学过技术对工业化工应用具有前景.
科学领域:
- 环境工程 环境工程
- 电化学 电化学 电化学
- 水处理 处理水的方法
背景情况:
- 电化学过技术的扩展对于实际应用至关重要.
- 来自化学工业的高盐度反透缩物 (ROC) 构成了重大处理挑战.
研究的目的:
- 评估试点规模的Ti/Pd反应电化学膜 (REM) 系统的性能,用于处理真正的高盐度ROC.
- 确定负责污染物降解的反应性物种,并评估处理效率.
主要方法:
- 一个试点规模的Ti/Pd REM系统使用了12个模块 (总REM面积为0.144平方米).
- 废水处理是在90L/m2·h的膜流量和5V的电池电压下进行的.
- 确定了反应性氧物种,并使用光谱和FT-ICR-MS分析了污染物氧化.
主要成果:
- 该Ti/Pd REM系统实现了82.3 ± 1.9%的COD和46.7 ± 5.6%的TN去除.
- 能量消耗量为0.045千瓦时/g-COD.
- 单片氧 (1O2) 和反应性物种被确定为关键反应剂.
- 类似酸的物质和不和芳香化合物被有效氧化.
结论:
- 试点规模的Ti/Pd REM技术证明了高盐度ROC的有效电化学降解.
- 该系统显示出处理具有挑战性的工业废水流的巨大潜力.
- 在化学工业废水处理中进一步应用REM技术是有希望的.
相关概念视频
Electrolysis
26.4K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
26.4K
Osmosis and Osmotic Pressure of Solutions
40.1K
A number of natural and synthetic materials exhibit selective permeation, meaning that only molecules or ions of a certain size, shape, polarity, charge, and so forth, are capable of passing through (permeating) the material. Biological cell membranes provide elegant examples of selective permeation in nature, while dialysis tubing used to remove metabolic wastes from blood is a more simplistic technological example. Regardless of how they may be fabricated, these materials are generally...
40.1K
Controlled-Potential Coulometry: Electrolytic Methods
173
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
173
Interfacial Electrochemical Methods: Overview
250
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
250
Potentiometry: Membrane Electrodes
583
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
583


