短时间电压变化对VSC-HVDC性能的影响
Reem A Mostafa1, Adel Emary2, A Sayed3
1Electrical Power and Machines Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt. 2101305@eng.asu.edu.eg.
Scientific reports
|December 28, 2023
概括
这项研究研究了电压变化如何影响连接异步电网的VSC-HVDC系统. 结果显示,这些系统在短期电压下降和膨胀期间难以保持稳定.
科学领域:
- 电气工程 电气工程
- 电力系统工程 电力系统工程
- 整合可再生能源的整合
背景情况:
- 全球能源需求的增长需要增加可再生能源的整合.
- 通过高压直流 (HVDC) 系统相互连接电网对于电网的稳定性和效率至关重要.
- 在HVDC系统中的电源电子设备可能会导致电源质量问题,如电压下降和膨胀.
研究的目的:
- 分析连接两个异步交流电网的电压源转换器-HVDC (VSC-HVDC) 系统的动态响应.
- 为了研究系统在短时间电压变化 (和膨胀) 下的稳定性.
- 为了评估操纵的交流源电压对系统性能的影响.
主要方法:
- 使用MATLAB/Simulink.模拟一个VSC-HVDC系统.
- 引入短时间的电压下降和系统的膨胀.
- 在转换器站监测和记录主动/反应功率和交流/直流电压.
主要成果:
- 记录了VSC-HVDC系统对电压变化的反应.
- 该研究确定了操纵交流电压对功率和电压水平的影响.
- 该系统对短期电压干扰的弹性有限.
结论:
- 连接异步电网的VSC-HVDC系统对电压下降和膨胀很敏感.
- 系统稳定性受到普遍的电力质量问题的挑战.
- 可能需要进一步的研究来提高这些系统对抗电压干扰的稳定性.
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
147
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
147
Power System Three-Phase Short Circuits
88
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Generator Voltage Control
155
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
155
Series R—L Circuit Transients
102
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
102
Energy Losses in Transformers
876
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
876
Insulation Coordination
137
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
137