心脏起器是患者可能需要中央静脉接入口的潜在问题来源
Marek Czajkowski1, Anna Polewczyk2,3, Wojciech Jacheć4
1Department of Cardiac Surgery, Medical University of Lublin, Lublin, Poland.
Cardiovascular diagnosis and therapy
|January 1, 2024
概括
在患有心脏植入式电子设备 (CIED) 的患者中,依赖性静脉阻塞很常见,可能会阻碍中央静脉接入装置 (CVAD) 的放置. 在这些患者的CVAD插入之前,建议进行静脉扫描.
科学领域:
- 心血管医学 心血管医学
- 干预性放射学 干预性放射学
- 血管接入 血管接入
背景情况:
- 依赖性静脉阻塞 (LDVO) 可以使中央静脉接入装置 (CVAD) 的插入复杂化.
- 心脏植入式电子设备 (CIED) 经常与静脉狭窄有关.
研究的目的:
- 评估在CIED患者中成功植入CVAD的可能性.
- 评估CIEDs对CVAD安置静脉通透性的影响.
主要方法:
- 追溯队列研究分析了从经过静脉取 (TLE) 的患者中3,075个静脉图.
- 评估了静脉通透性与成功安置CVAD之间的关系.
- 与CIED放置相比,对ipsilateral和contralateral两侧的评估静脉狭窄.
主要成果:
- 75.38%的患者没有表现出 ipsilateral CVAD 端口植入的静脉学障碍.
- 在CIED左侧,显著的下静脉狭窄比头静脉狭窄 (28.63%) 更频繁 (55.29%).
- 对侧静脉狭窄发生在少数患者中 (例如,下静脉的35 (2.35%).
- 在75.38% (两侧) 和97.91% (两侧) 的病例中,CVAD插入被认为很容易,在16.62% (两侧) 的病例中,难度或不可能.
结论:
- 在CIED患者中,依赖于的静脉阻塞是常见的发现.
- 反侧侧的胸静脉也可以显著缩小.
- 建议在CIED患者的CVAD插入前进行手术前静脉扫描,特别是那些长时间停留或CIED后移除的患者.
相关概念视频
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
165
Parenteral Nutrition (PN) delivers essential nutrients directly into the bloodstream, bypassing the digestive system. It is commonly used for individuals with severe digestive disorders or conditions that prevent normal nutrient absorption.
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
165
Assessment of the Cardiovascular System III: Palpation
342
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
342