使用UPFC进行分析研究和真实模拟,以提高老化核设施的安全性
Ahmed S Adail1, Yasser M Ammar2, Adel A Elbaset3,4
1Nuclear Fuel Technology Department, Hot Labs Center, Egyptian Atomic Energy Authority (EAEA), Inshas, Egypt. ahmed.adail@eaea.org.eg.
Scientific reports
|January 3, 2024
概括
这项研究通过使用统一电力流量控制器 (UPFC) 提高电力质量,提高核设施的安全性和性能. 拟议的方法优化了UPFC的放置,以确保老式电气设备的可靠运行.
科学领域:
- 电气工程 电气工程
- 核工程 核工程是指核工程.
- 电力系统 电力系统
背景情况:
- 由于电力质量问题,老旧的核设施面临性能和安全挑战.
- 降低电源质量加快了电气设备的老化,增加了运营风险.
- 保持稳定的电力质量对于核基础设施的寿命和安全至关重要.
研究的目的:
- 提高老化的核设施 (NF) 的性能和安全性.
- 调查电力质量改善对电气设备寿命的影响.
- 评估和实施一种新的技术,以提高NF的电力质量.
主要方法:
- 在现实世界NF中测量和分析电力质量事件.
- 在统一功率流量控制器 (UPFC) 分配中应用部分群集优化技术.
- 使用Simulink-MATLAB模拟一个真实的NF,并采用新的UPFC配置.
主要成果:
- 拟议的部分小群优化技术有效地确定了最佳的UPFC放置.
- 模拟显示,在NF中,电源质量得到了显著的改善.
- 该战略在提高老旧核设施的安全性和运行寿命方面被证明是有效的.
结论:
- 优化UPFC分配是改善NF电源质量的可行策略.
- 提高电源质量直接有助于延长关键电气设备的寿命和安全性.
- 开发的方法为管理老化的核电基础设施中的电力质量提供了强大的解决方案.
相关概念视频
Nuclear Power
7.8K
Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
7.8K
Multimachine Stability
163
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
163
Fast Decoupled and DC Powerflow
197
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
197
Load-frequency control
165
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
165
Power System Three-Phase Short Circuits
88
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Power Factor Correction
179
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
179