随着光伏在工业中的使用,降低了需求费用
Ángel Ordóñez1,2, Esteban Sánchez2, Juan Carlos Solano1
1Facultad de la Energía, Universidad Nacional de Loja, Avda. Pío Jaramillo Alvarado, 110110 Loja, Ecuador.
Heliyon
|January 3, 2024
概括
光伏 (PV) 可以显著降低工业需求费用. 本研究提出了一种优化合同功率的方法,在不连续运营中显示了高达28%的潜在节约,并且在一致需求模型中获得了更高的收益.
科学领域:
- 能源经济学 能源经济学
- 可再生能源系统可再生能源系统
- 工业能源管理 工业能源管理
背景情况:
- 对工业和商业消费者来说,需求收费是相当大的成本,往往不被充分理解.
- 光伏 (PV) 系统对这些电荷的影响尚未得到广泛认可.
- 目前评估光伏对需求成本影响的方法有限.
研究的目的:
- 开发和验证一种方法来评估光伏对降低需求成本的影响.
- 为了优化工业消费者与光伏装置的合同电力.
- 为了比较对光伏用户的巧合和非巧合需求模型的有效性.
主要方法:
- 探索性数据分析技术的应用.
- 开发一种方法来评估光伏对需求费的影响.
- 涉及五个来自西班牙不同行业的工业消费者的案例研究.
- 对一致和非一致的需求收费模型进行比较分析.
主要成果:
- 在连续运营行业的需求费用上节省了5%-11%的成本.
- 对于不连续运营的行业,潜在的节约高达28%.
- 如果合同功率低于最佳水平,可以实现更大的节约.
- 巧合需求模式通常为光伏用户提供更高的节省.
结论:
- 太阳能光伏系统为降低工业需求负担提供了巨大的潜力.
- 拟议的方法有效评估光伏影响并优化合同功率.
- 需求收费模式的选择 (一致性与非一致性) 显著影响储蓄潜力.
更多相关视频
相关概念视频
Power Factor Correction
179
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
179
P-N junction
537
A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
537
Reducing Line Loss
154
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
154
Secondary Distribution
87
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
87
Electrical Energy
1.2K
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules.
1.2K
Electrolysis
26.4K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
26.4K


