较小的数字的宽度的比较X光学分析近距离的头头
Kushkaran Kaur1, Asher Cherian1, Russell J Hill1
1*Department of Podiatric Surgery, Temple University School of Podiatric Medicine, Philadelphia, PA.
Journal of the American Podiatric Medical Association
|January 3, 2024
概括
小脚近腰头的宽度从第二到第四个脚下降,然后增加到第五个脚,这表明解剖学因素有助于足部医学中的数字形.
科学领域:
- 足部医学和外科手术
- 放射学分析 放射学分析
- 人体解剖学 解剖学 解剖学
背景情况:
- 数字形在足部医学中很常见.
- 对于这些情况,经常需要手术干预.
- 了解形的解剖基础至关重要.
研究的目的:
- 为了比较较较小的数字近似状头的放射宽度.
- 为了调查对数字形的解剖学贡献.
主要方法:
- 分析了150张具有数字变形的脚部负载放射图.
- 计算机化数字软件用于测量较小数字近接尾头的最大宽度.
主要成果:
- 平均宽度:第二位数字9.74 ± 0.87毫米,第三位数字9.00 ± 0.91毫米,第四位数字8.49 ± 1.01毫米,第五位数字8.67 ± 0.89毫米.
- 头的宽度从第2到第3位 (P < .001) 和第3到第4位 (P < .001) 显著减少.
- 宽度从第4位数增加到第5位数 (P = .032).
结论:
- 放射测量支持对数字形的解剖学贡献.
- 角头宽度的模式 (下降然后增加) 可能在形发育中起作用.
相关概念视频
Imaging Biological Samples with Optical Microscopy
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Confocal Fluorescence Microscopy
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Overview of Electron Microscopy
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...


