使用EDaViS软件在临床设置中可视化复杂的挥发性代谢学数据的协议
Leo Ruehrmund1, Patricia Fuchs1, Julia Bartels1
1Rostock Medical Breath Research Analytics and Technologies (RoMBAT), Dept. of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Rostock University Medical Centre, 18057 Rostock, Germany.
STAR protocols
|January 3, 2024
概括
本研究介绍了一种使用早期数据可视化脚本软件可视化复杂的挥发性代谢学数据的协议. 该工具简化了用于临床应用的时间解析的omics数据的分析.
科学领域:
- 生物化学 生物化学
- 生物信息学是一种生物信息学.
- 临床科学 临床科学
背景情况:
- 代谢学产生复杂的数据集.
- 在临床环境中,可视化挥发性omics数据带来了挑战.
研究的目的:
- 介绍一个可视化复杂挥发性代谢学数据的协议.
- 介绍早期数据可视化脚本作为一个用户友好的工具.
主要方法:
- 对于挥发性欧米克数据集的数据表化.
- 调整时间解析数据的视觉输出.
- 适应四个基本的软件功能.
主要成果:
- 展示用于数据可视化的简单图表和图表.
- 成功地调整软件功能以提高实用性.
结论:
- 早期数据可视化脚本为分析挥发性代谢学数据提供了一种简单的方法.
- 该协议有助于在临床研究中解释复杂的奥米克数据.
更多相关视频
相关概念视频
Enzyme-linked Receptors
Enzyme-linked receptors are proteins that act as both receptor and enzyme, activating multiple intracellular signals. This is a large group of receptors that include the receptor tyrosine kinase (RTK) family. Many growth factors and hormones bind to and activate the RTKs.
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Effects of EDTA on End-Point Detection Methods
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Automated Microbial Diagnostics
Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...