使用一个金属入口卷着铜线作为离子源环境电离质谱的离子源
Chi-Feng Tu1, Yu-Chie Chen1,2
1Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan.
Analytical chemistry
|January 3, 2024
概括
一个经过修改的质谱输入口,用铜线绕起来,作为一种新的离子源. 这种方法使得各种分析物的敏感检测和UV-Vis光谱的同时分析成为可能.
科学领域:
- 分析化学 分析化学
- 质谱测量质量谱测量
- 频谱学是一种光谱学.
背景情况:
- 环境电离质谱 (MS) 通常使用定制入口进行样本引入.
- 现有的方法通常需要专门的接口,用于不同的电离技术.
研究的目的:
- 开发一种用于环境电离质谱的新型,多功能离子源.
- 为了实现使用质谱和紫外可见吸收光谱的同时分析.
- 为了实现对极性和非极性分析物的敏感检测.
主要方法:
- 在质谱学中,一个用薄铜线绕的金属入口被用作直接离子源.
- 将高电压应用于修改后的输入口,以诱导冠状放电类电离.
- 与紫外线可见吸收光谱的合是使用相同的修改入口作为接口实现的.
- 样品滴滴被沉积在离子化改性入口附近的介电基板上.
主要成果:
- 修改后的入口成功地产生了对挥发性/半挥发性分析物的气相电离的冠状放电.
- 在水样中实现了青的低检测极限 (∼1 pM).
- 证明了同时采用质谱和UV-Vis光谱法获取数据.
- 从混合物中检测到单个质谱中的极性和非极性分析物.
- 在香料样本中成功检测到子[a]烯,证实了它对复杂矩阵的适用性.
结论:
- 一个铜线绕的金属入口作为环境质谱的有效和多功能离子源.
- 这种方法简化了仪器仪表,并允许同时进行多技术分析.
- 该方法适用于复杂样品中不同分析物的敏感检测和同时分析.
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
745
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
745
Chemical Ionization (CI) Mass Spectrometry
751
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
751
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
626
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
626
Electrospray Ionization (ESI) Mass Spectrometry
851
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
851
Mass Spectrometers
5.5K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.5K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
478
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
478