在消化过程中对基于牛奶的口服配方进行操作分析,使用同步龙小角度X射线散射与低频拉曼光谱学相结合
Ka Rlis Be Rziņš1, Peter Meiland1,2, Anas Aljabbari1
1Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2100, Denmark.
Analytical chemistry
|January 4, 2024
概括
结合低频拉曼射线 (LFR) 和小角度X射线散射 (SAXS),在消化过程中有效地分析基于牛奶的配方中的脂质和药物行为. 这种双重方法提高了对超分子结构和药物相互作用的理解.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
- 生物物理化学 生物物理化学
背景情况:
- 基于脂质的口服配方对于药物输送至关重要.
- 了解酶性消化过程中的药物行为是配方开发的关键.
- 基于牛奶的配方由于复杂的脂质结构而存在独特的挑战.
研究的目的:
- 评估一种联合的低频拉曼 (LFR) 和直线小角度X射线散射 (SAXS) 方法.
- 为了确定基于牛奶的口服配方在酶性脂解期间的脂质和药物行为.
- 评估辛纳瑞的溶解动态和对牛奶消化产品的影响.
主要方法:
- 低频拉曼 (LFR) 探头与小角度X射线散射 (SAXS) 束线的合.
- 乳制品口服配方的酶性消化,含有肉.
- 使用LFR和SAXS进行超分子结构和药物行为的分析.
主要成果:
- 萨克斯在区分消化过程中形成的液晶晶体组件方面表现出色.
- LFR提供了关于肥形成的补充数据.
- LFR有效地区分了药物溶解和沉,SAXS的这种差异不太明显.
结论:
- 结合的LFR和SAXS方法为研究基于脂质的配方提供了显著的优势.
- 这种组合技术有助于理解药物行为和消化过程中的超分子变化.
- 这些发现有助于将基于同步仪的结果转化为常规的实验室和工业分析.
更多相关视频
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
12.4K
11:27A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
2.1K
相关概念视频
Raman Spectroscopy: Overview
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Methods for Studying Drug Absorption: In situ
In situ experiments, such as the Doluisio method and Single-Pass Perfusion technique, provide critical insights into drug uptake by simulating in vivo conditions for drug absorption.
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...