增强现实辅助脚螺丝放置的准确性:一个系统的审查
Salma Youssef1, Jake M McDonnell2,3, Kielan V Wilson4,5
1School of Medicine, University College Dublin, Belfield, Dublin, Ireland.
概括
增强现实外科导航 (ARSN) 在脊椎外科手术中显示出足螺丝放置的高精度. 虽然有效,但需要进一步的研究来直接比较ARSN与传统方法.
科学领域:
- 脊椎手术和外科导航技术.
背景情况:
- 自由手脚架螺丝摆放带有风险,因为它靠近神经和血管结构.
- 增强现实手术导航 (ARSN) 越来越多地用于脊柱手术,但其准确性需要进一步调查.
研究的目的:
- 为了确定增强现实外科导航 (ARSN) 对于脚螺杆放置的整体准确性.
- 分析各种准确度指标,包括螺丝放置,破裂和偏差.
主要方法:
- 对Medline/PubMed,Cochrane和Embase数据库进行了系统审查.
- 提取了关于脚螺丝精度,破裂 (格茨贝恩-罗宾斯分类) 和偏差的数据.
- 准确性被定义为格茨贝因-罗宾斯0级和1级事件的总和.
主要成果:
- 20项研究报告了临床准确的脚螺杆放置情况.
- 2095个螺丝中的93.1%被认为是临床准确的.
- 平均线性偏差在1.3到5.99毫米之间,角度偏差在1.6°到5.88°之间.
结论:
- 在脊椎手术中,ARSN 显示了足螺丝放置的显著整体准确性.
- 需要进一步的前性研究,直接比较ARSN准确性与传统的脚螺丝安置技术.
相关概念视频
Stability of structures
In mechanical engineering, the stability of systems under various forces is critical for designing durable and efficient structures. One fundamental way to explore these concepts is by analyzing systems like two rods connected at a pivot point, O, with a torsional spring of spring constant k at the pivot point. This system is similar in appearance to a scissor jack used to change tires on a car. In this case, the arms of the linkage (equivalent to the rods in this system) are entirely vertical,...
Distance Corrections
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Errors in Taping
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
Common Leveling Mistakes and Errors
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Adjusting a Traverse
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...