在液体阿贡中首次观察中性制动辐射电发光
A Bondar1, A Buzulutskov1, E Frolov1
1Budker Institute of Nuclear Physics SB RAS, Lavrentiev avenue 11, 630090 Novosibirsk, Russia and Novosibirsk State University, Pirogova street 2, 630090 Novosibirsk, Russia.
Physical review letters
|January 5, 2024
概括
首次在液体中观察到来自中性制动辐射 (NBrS) 的电发光 (EL). 这一发现证实了理论预测,并为了解贵族液体中的光辐射开辟了新的途径.
科学领域:
- 物理 物理学 物理
- 材料科学 材料科学 材料科学
背景情况:
- 贵重气体中的电光发射 (EL) 被理解为涉及中性制动辐射 (NBrS) 效应.
- 理论模型预测NBrS EL也应该出现在贵族液体中.
研究的目的:
- 通过实验证实贵族液体中NBrS EL的存在.
- 开发和验证NBrS EL在贵族液体中的理论模型.
主要方法:
- 使用气体电子乘数 (GEM) 和厚的GEM结构观察液体中的可见范围EL.
- 科恩-莱克纳和阿特拉泽夫的理论框架的应用.
- 测量观察到的EL的绝对光输出率.
主要成果:
- 在90kV/cm的电场下,在液体中观察到可见范围的电发光 (EL).
- 测量的光产量与使用动量转移横截面用于电子散射时的理论预测密切匹配.
- 这证实了NBrS EL在贵族液体中的存在和机制.
结论:
- 中性制动辐射 (NBrS) 效应是高贵液体中电发光 (EL) 的可行机制.
- 在液体中进行的实验观测验证了理论模型,并表明在高贵液体系统中具有更广泛的适用性.
- 选择截面 (动量转移与能量转移) 对于准确的NBrS EL理论建模至关重要.
相关概念视频
Atomic Emission Spectroscopy: Overview
2.2K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.2K
Atomic Fluorescence Spectroscopy
386
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
386
Atomic Absorption Spectroscopy: Radiation and Light Sources
403
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
403
Atomic Emission Spectroscopy: Instrumentation
486
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
486
Atomic Emission Spectroscopy: Lab
165
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
165
Photoluminescence: Applications
403
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
403