基于SPR和MMI的纤维传感器,用于同时测量胆固醇度和温度
Wanlu Zheng1, Bo Han2, Ya-Nan Zhang3
1College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China.
Analytica chimica acta
|January 5, 2024
概括
这项研究介绍了一种新的光纤传感器,用于同时测量胆固醇和温度. 该传感器利用表面等离子共振和多模式干扰效应,在生物医学应用中提供高灵敏度和精度.
科学领域:
- 光电学是指光电子产品.
- 生物医学传感传感器
- 纳米材料是一种纳米材料.
背景情况:
- 精确的胆固醇监测对于心血管健康至关重要.
- 现有的传感器往往受到交叉灵敏度和有限的精度的影响.
- 生物样本分析需要同时测量温度.
研究的目的:
- 开发一种双参数光纤传感器,用于同时检测胆固醇和温度.
- 为了提高传感器的灵敏度和选择性,使用表面等离子体共振 (SPR) 和多模干扰 (MMI) 效应.
- 为了解决温度和胆固醇测量之间的交叉敏感性的挑战.
主要方法:
- 使用多模纤维 (MMF) -Au薄膜涂层空心纤维 (HCF) -MMF结构制造一个内纤维传感器.
- 用Au纳米粒子/β-环极 (AuNPs/β-CD) 复合物涂覆HCF,通过SPR检测胆固醇.
- 将糖氨酸纳入HCF以通过MMI传感温度,从而实现双参数测量.
主要成果:
- 传感器显示SPR的波长偏移为12.7nm,MMI的波长偏移为7.9nm,胆固醇度从0到500nm的变化.
- 在30°C-46°C范围内观察到温度敏感度为-0.9nm/°C (SPR) 和2.64nm/°C (MMI).
- 该传感器在检测血清环境中的胆固醇方面表现出卓越的稳定性,选择性和可重复性.
结论:
- 设计的纤维传感器成功地实现了同时和灵敏地测量胆固醇度和温度.
- SPR和MMI效应的结合,以及AuNPs/β-CD和甘油,为双参数传感提供了一个强大的平台.
- 这种传感器在生物医学诊断和健康监测方面具有很大的应用潜力.
相关概念视频
Temperature Measurement Sites
1.7K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.7K
Assessing Body Temperature - Oral
745
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...